GUIDE TO INSTALLATION AND OPERATION
RCP-200 |
11
16.
Controls Lock
This button is used to lock and unlock the rotary encoders [18].
•
Lights up green when OFF – the 8 control knobs are enabled allowing paramameter adjustments.
•
Lights up red when ON – the 8 control knobs are disabled, protecting the parameters from
accidental misadjustement.
If a control knob is manipulated while Controls Lock is ON, the button flashes to indicate that the
controls need to be unlocked before the action can be taken.
17.
Right LCD
The Right LCD is physically identical to the Left LCD.
The upper third section of the Right LCD is used
to show device identification and navigation tabs for access to different parameter groupings. The
screen is touch-sensitive.
The lower 2/3
rd
of the Right LCD is used to show operating controls, status displays and graphics that
allow the user to adjust and operate the device. All adjustments are performed using the row of eight
control knobs located beneath the screen. The relationship between the control knobs and the screen
elements they control will be evident from the screen layout, but in general terms, a knob can operate
on elements located in the segment of the screen that lies immediately above it.
Touch is used only to focus on control segments contain sliders. The segment of the screen that is in
focus is highlighted by a mauve border. Note that manipulating the control knob associated with a
segment will shift focus to that segment, including those that will not respond to touch.
18.
Knob Matrix
Eight knobs are provided to allow direct control of elements displayed in the Right LCD, as described
above (17). Each knob can be turned, and has an integrated push-button. Exact behavior varies with
the parameter being controlled.
In general terms:
•
Turn the knob to adjust a parameter value, or to move up and down a displayed list.
•
Push the knob to change the value of a push-button switch in the display
•
Push and hold the control knob for about 1.5 seconds to retrieve and insert a factory-defined
nominal value or a user default value for the parameter in focus, if one is available. User default
or nominal values are only available for parameters that can be adjusted using a slider control.
•
If you manipulate the knob associated with a sector of the control screen, you will move the focus
to that sector
16
18
upper
1
/
3
lower
2
/
3
17