GUIDE TO INSTALLATION AND OPERATION
14
| XVP-3901
The pinout of the D-SUB connector for both
110
Ω
and
75Ω
rear panels is shown in this chart.
Fiber I/O – Fiber-optic inputs and outputs
Rear panels whose part number ends in –F incorporate a fiber optic interface. The interface consists of two parts:
•
A socket on the rear panel into which an SFP interface module is plugged
•
An SFP (Small Form-factor Pluggable) module into which the optical fibers are plugged, and which incorporates
the optical/electrical interface
The optical fibers must be terminated in an LC connector.
See
Annex 3
for instructions on installing and removing the SFP interface module, and for plugging and unplugging
the LC-terminated fibers.
The current SFP modules supported are:
SFP Modules
Description
SFP-RR-LC
Dual Rx module with LC connector
SFP-TT-S13S13-LC
Dual Tx module at 1310 nm with LC connector
SFP-RT-S13-LC
Single Rx and Tx transceiver module at 1310 nm with LC connector
SFP-R-LC
Single Rx module with LC connector
SFP-T-S13-LC
Single Tx module at 1310 nm with LC connector
XVP-3901-110-3DRP-F
110 Ohm rear
Pin #
XVP-3901-75-3DRP-F
75 Ohm rear
AES IN 1 (Hi)
1
AES IN 1
AES IN 1 (Lo)
10
GND
AES IN 2 (Hi)
2
AES IN 2
AES IN 2 (Lo)
11
GND
AES IN 3 (Hi)
3
AES IN 3
AES IN 3 (Lo)
12
GND
AES IN 4 (Hi)
4
AES IN 4
AES IN 4 (Lo)
13
GND
AES OUT 1 (Hi)
5
AES OUT 1
AES OUT 1 (Lo)
14
GND
AES OUT 2 (Hi)
6
AES OUT 2
AES OUT 2 (Lo)
15
GND
AES OUT 3 (Hi)
7
AES OUT 3
AES OUT 3 (Lo)
16
GND
AES OUT 4 (Hi)
8
AES OUT 4
AES OUT 4 (Lo)
17
GND
GND
19, 20, 21,
22, 23, 24,
25, 26
GND
N/C
9, 18
N/C