MIOX RIO-S Series Operators Manual
102-00130-D
Page
65
Rupture Disk
Each cell bank of the RIO-S OSG is equipped with a designated rupture disk. The rupture
disk is designed to prevent excessive pressure build up inside the cell. If the cell pressure
exceeds 25 PSI, a diaphragm inside of the rupture disk union bursts. Flow is routed
towards leak detector sensing band, which will trigger Leak Detect Fault. The Leak Detect
causes the system to shut down immediately. On the HMI, “Leak Detect – Bank X” is
displayed. In the event of a Leak Detect Fault, the moisture detected on the sensing band
could be the result of the rupture disk bursting or a leak from within the cell bank. Always
check the condition of the rupture disk inside the union housing to verify it has not blown.
If not, then the water detected is from a cell or plumbing leak. See Leak Detection for more
details.
Figure 28: Rupture Disk and Leak Detect Assemblies
Replacing the Rupture Disk Diaphragm
1.
Put the system in STOP by pressing the START/STOP button on HMI.
2.
Open both inlet and oxidant drain valves to drain the bank associated with the leak.
3.
Remover the oxidant side panel associated with the leak.
Содержание RIO-S Series
Страница 9: ...MIOX RIO S Series Operators Manual 102 00130 D Page 9 Figure 2 RIO S OSG Space Requirements...
Страница 30: ...MIOX RIO S Series Operators Manual 102 00130 D Page 30 Figure 13 External Plumbing Electrical Overview Rear...
Страница 37: ...MIOX RIO S Series Operators Manual 102 00130 D Page 37 Figure 19 Brine Pressure Boost System...
Страница 75: ...MIOX RIO S Series Operators Manual 102 00130 D Page 75 X mg L chlorine concentration Y gph flow...