MIOX RIO-S Series Operators Manual
102-00130-D
Page
55
Fault Name
Condition
Time
Delay
(sec)
Cell
Power
Removed
Flush
Removed
Auto
Retry
3x
Low Low Water Flow
50% decrease in water
flow rate – immediate
response
1 YES NO NO
High Flow
Flow rate increase
above specified set-
point
5 NO NO NO
Low Water
Temperature
Feed water
temperature less than
40° F.
90 NO
NO
YES
High Water
Temperature
Inlet water temp
greater than 95° F.
300 NO
NO
YES
High Flow Control
Signal
Flow control is not
reaching target set-
point
30 YES
NO
NO
Hi Diode Temp
Rectifier temperature
switch tripped.
1 NO NO NO
Hardness Monitor
Fault
Hardness monitor trips
while running.
1 NO NO NO
Hydrogen Monitor
Fault
Hydrogen monitor trips
while running.
1 YES YES NO
Low Ext. Dilution Air
Flow
Dilution air status
signal off when Dilution
air enable signal on.
1 YES NO NO
Low UPS Battery
Voltage
UPS Battery has failed
or lost
power/connection
1
YES
NO
NO
Phase Monitor Fault
Improper phase or
voltage detected
1 NO NO NO
Current Sensor Signal
Loss
Invalid or no signal
from current sensor
1 NO NO NO
Undefined Tank Level Incorrect wiring of
floats
1 NO NO NO
Loss of SCADA
Connection to SCADA is
lost
5 NO NO NO
Turck Module #2
Fault
Invalid or no signal
from #2 Turck Module
1 YES NO NO
Turck Module #4
Fault
Invalid or no signal
from #4 Turck Module
1 YES NO NO
Turck Module #6
Fault
Invalid or no signal
from #6 Turck Module
1 YES NO NO
Power Cycle Detected Loss of power or power
surge
1 NO NO NO
Содержание RIO-S Series
Страница 9: ...MIOX RIO S Series Operators Manual 102 00130 D Page 9 Figure 2 RIO S OSG Space Requirements...
Страница 30: ...MIOX RIO S Series Operators Manual 102 00130 D Page 30 Figure 13 External Plumbing Electrical Overview Rear...
Страница 37: ...MIOX RIO S Series Operators Manual 102 00130 D Page 37 Figure 19 Brine Pressure Boost System...
Страница 75: ...MIOX RIO S Series Operators Manual 102 00130 D Page 75 X mg L chlorine concentration Y gph flow...