background image

118

SCAN JOB FILE LIST — 120/220 (6x8)

&DWHJRU\

-REQDPH

,QSXW5HV 2XWSXW5HV

0DJ

8QLW

,QSXW6L]H

/RFN,1

2XWSXW 6L]H

/RFN287

,QSXW

:

+

:

+

:

+

'HIDXOW

'HIDXOW

SL[HO

2))

2))

&RORU/DVHU3ULQWHU

$)XOO

PP

2))

21

$)XOO

PP

2))

21

$+DOI

PP

2))

21

$4XDWHU

PP

2))

21

/HWWHU)XOO

LQFK

2))

21

/HWWHU+DOI

LQFK

2))

21

/HWWHU4XDWHU

LQFK

2))

21

3KRWRVHQVLWLYH

$)XOO

PP

2))

21

$)XOO

PP

2))

21

$)XOO

PP

2))

21

/HWWHU)XOO

LQFK

2))

21

/HWWHU+DOI

LQFK

2))

21

/HWWHU4XDWHU

LQFK

2))

21

[

LQFK

2))

21

[

PP

2))

21

[

PP

2))

21

[

PP

2))

21

/

PP

2))

21

3RVW&DUG[

LQFK

2))

21

,QN-HW 

6XSHU%

PP

2))

21

'\H6XE3ULQWHU

$)XOO

PP

2))

21

$)XOO

PP

2))

21

$+DOI

PP

2))

21

$4XDUWHU

PP

2))

21

/HWWHU)XOO

LQFK

2))

21

/HWWHU+DOI

LQFK

2))

21

/HWWHU4XDWHU

LQFK

2))

21

3KRWR[

PP

2))

21

3KRWR[

PP

2))

21

:HE3DJH

[

SL[HO

2))

21

[

SL[HO

2))

21

[

SL[HO

2))

21

[

SL[HO

2))

21

[

SL[HO

2))

21

[

SL[HO

2))

21

[

SL[HO

2))

21

3KRWR&'

3KRWR&'[

SL[HO

2))

21

3KRWR&'[

SL[HO

2))

21

3KRWR&'[

SL[HO

2))

21

6FUHHQ

[

SL[HO

2))

21

[

SL[HO

2))

21

[

SL[HO

2))

21

[

SL[HO

2))

21

[

SL[HO

2))

21

[

SL[HO

2))

21

[

SL[HO

2))

21

[

SL[HO

2))

21

[

SL[HO

2))

21

'RFXPHQW

$+DOI

PP

2))

21

$4XDWHU

PP

2))

21

$(LJKWK

PP

2))

21

/HWWHU+DOI

LQFK

2))

21

/HWWHU4XDWHU

LQFK

2))

21

/HWWHU(LJKWK

LQFK

2))

21

Содержание DiMAGE DiMAGE Scan Multi PRO

Страница 1: ...INSTRUCTION MANUAL E 9224 2887 11 H A108...

Страница 2: ...M are trademarks of registered trademarks and technolgies of Applied Science Fiction Inc in U S A Other corporate and product names are the trademarks and registered trademarks of their respective com...

Страница 3: ...inflammable products such as alcohol benzine or paint thinner to clean the product The use of inflammable cleaners and solvents may cause an explosion or fire Do not damage twist modify heat or place...

Страница 4: ...achments with glass and glassless Film Masks Ultra SCSI D sub half pitch 50 pin connector cable IEEE1394 connector cable AC power cord CD ROM for DiMAGE Scan Multi PRO software and PDF manuals Warrant...

Страница 5: ...required system and the names of the parts This section describes how to set up the scanner Final Scan 10 13 This section describes how to perform the index scan 41 This section describes how to perfo...

Страница 6: ...23 LAUNCHING THE SOFTWARE WINDOWS 26 Launching the TWAIN Drivers 26 Launching the Utility Software 26 LAUNCHING THE SOFTWARE MACINTOSH 27 Launching the Plug in 27 Launching the Utility Software 27 MAI...

Страница 7: ...47 LOADING THE INDEX IMAGE FILE 48 PREVIEW SCAN PRESCAN WINDOW 50 The Prescan Tab Part Names of Parts 50 MAKING A PRESCAN 51 ROTATING THE IMAGE 52 FLIPPING THE IMAGE 53 FULL SCREEN VIEWING MAGNIFYING...

Страница 8: ...riation Dialog Box Names of Parts 74 Selecting the Correction Item 74 Changing the correction increments 74 Colour Balance Correction 75 Brightness Contrast Correction 75 Saturation Correction 76 Rese...

Страница 9: ...starting a registered setting 104 APPENDIX IEEE 1394 INTERFACE 106 COLOUR MATCHING 107 Output Colour Space Setting 108 ICC Profile Setting 108 SCAN JOB FILE LIST 35 mm 110 SCAN JOB FILE LIST 120 220...

Страница 10: ...k space About 6 GB or more of available hard disk space when scanning with 16 bit output or using the Digital ICE ROC GEM functions 8 GB or more is recommended Recommended Board Adaptec SCSI CARD 1916...

Страница 11: ...Photoshop Ver 5 02 Ver 5 5 and Ver 6 0 Photoshop 5 0LE About 2GB or more of available hard disk space About 6 GB or more of available hard disk space when loading with 16 bit or using the Digital ICE...

Страница 12: ...12 SCANNER NAMES OF PARTS Film slot door Indicator lamp Film Holder Eject button Power switch SCSI ID switch IEEE 1394 interface connector Dip switches AC power socket SCSI Interface connector...

Страница 13: ...ONNECTING THE HARDWARE REMOVING THE OPTICS LOCKING SCREW LAUNCHING THE SOFTWARE INSTALLING THE SOFTWARE SETTING THE FILM FORMAT FILM TYPE SETTING THE PREFERENCES INSERTING THE FILM HOLDER LOADING THE...

Страница 14: ...optics to the locking position to prevent damage and then tighten the optics locking screw on the bottom panel of the scanner 1 When the DiMAGE Scan Multi PRO Utility Software is in operation Windows...

Страница 15: ...g SCSI as the interface to be used to connect the scanner to a computer If this scanner is the last device of the SCSI chain set to ON Switch No 1 is factory preset to ON Switch No 2 Auto Power Save S...

Страница 16: ...es in the same SCSI chain cannot share a SCSI ID A SCSI ID is a unique address you assign to each SCSI device connected to your computer The SCSI ID range of your computer is from 0 to 7 however some...

Страница 17: ...SCSI cable to either SCSI port on the back of the scanner Either SCSI port can be used for other configurations there is no dedicated in or out port 3 Connect the other end of the SCSI cable to the SC...

Страница 18: ...TERFACE 6 Plug the power cord into the scanner s AC socket then plug it into a grounded outlet NOTE This device is to be used with a power source within the voltage as specified on the back of unit NO...

Страница 19: ...t may also be called FireWire Example Connect the IEEE 1394 Hub terminal 1 Turn the SCSI terminator switch Dip switch 4 to OFF 2 Connect one end of the IEEE 1394 cable to either IEEE 1394 port on the...

Страница 20: ...Turn on the computer to start Windows 2 Insert the DiMAGE Scan Multi PRO CD ROM into the CD ROM drive In a little while a splash screen for Setup will appear 3 Click on Starting up the DiMAGE Scan Mu...

Страница 21: ...file is positioned at D Driver English Setup exe and click OK In a little while a splash screen for Setup will appear After that continue to step 4 The drive name will differ depending on the System...

Страница 22: ...the descriptions in this manual assume the Twain data source setup has been selected Click Next to display the window for selecting the Program Folder 8 The name of the default Program Folder is displ...

Страница 23: ...the extensions 1 Turn on the DiMAGE Scan Multi PRO 2 Turn on the Macintosh and start up the Mac OS 3 Insert the DiMAGE Scan Multi PRO CD ROM into the CD ROM drive Dimage Scan Multi PRO will appear on...

Страница 24: ...Decline and the software will not be installed 9 Check the folder in which the software will be installed To change it select Select folder from the Install Location pop up menu then select an existi...

Страница 25: ...n a new folder titled DiMAGE Scan Multi PRO If Easy Install was chosen the DiMAGE Scan Multi PRO folder will contain the following items DS_MultiPRO Utility DS_MultiPRO Plug in and Read Me file 13 Dra...

Страница 26: ...the software through another application such as your image editing software LAUNCHING THE TWAIN DRIVER This manual uses Adobe Photoshop Ver 6 0 as the host application Commands may vary among applica...

Страница 27: ...Photoshop Ver 6 0 as the host application Commands may vary among applications 1 Launch Adobe Photoshop 2 Select File Import DS_MultiPRO Plug in The software is ready for use when the Main window app...

Страница 28: ...see page 63 Scan Setting part see page 92 Main Window part see below Holder Type list box Film format list box Index Scan button Prescan button Scan button Film Type list box Preferences button Close...

Страница 29: ...n the default setting The checkmark is not on the checkbox However if you intend to use the Autofocus function when scanning click on the checkbox of Auto Focus at Scan When using the Digital ICE ROC...

Страница 30: ...orm sampling 2 times 4 times Perform sampling 4 times 8 times Perform sampling 8 times 16 times Perform sampling 16 times The more times the image is sampled the longer the required time for scanning...

Страница 31: ...the slide mount Open the slide holder by pulling up the tab from underneath 2 Place the film in the film holder emulsion side down Make sure the film strip is under the two nouches at the top of the h...

Страница 32: ...n open the slide mount Open the slide holder by pushing up the tab from underneath 2 Place the slides within the indentations making sure they lie flat Insert the slides emulsion side down 3 Press the...

Страница 33: ...e of the film Align the mask with the attachment Fix the two protruding parts into the slots on the hinge side Fit the mask over the film guide and the two pins LOADING THE UNIVERSAL HOLDER UH P1 The...

Страница 34: ...e a film on the mask with the emulsion side down while aligning the lower side of the film with the film guide at the upper or lower side 5 Close the film cover of the holder until it clicks LOADING T...

Страница 35: ...he right side of the frame The scanning position will be determined by the film format selected on the main window Adjust the slide bars to determine the mounting position of the left side of the film...

Страница 36: ...m attachment with glass HA P1 or glassless HA P2 is installed remove it beforehand 2 Fit the two pins on the upper side of the film cover into the holes on the upper side of the holder until they clic...

Страница 37: ...he right lift the cover and remove the pins 2 While sliding the lever on the middle part of the holder to the right lift the attachment 5 Place a film on the mask with the emulsion side down while ali...

Страница 38: ...der at an angle 3 Gently push the holder into the scanner until the raised insertion mark is aligned with the film slot door The film holder will be automatically guided in past the mark If the holder...

Страница 39: ...formats and appropriate holders for scanning Selecting the Holder Type When 6x4 5 6x6 6x7 6x8 or 6x9 is selected in the film format select the holder type 1 Select the holder type from the drop down l...

Страница 40: ...2 1 Possible to scan the entire area at a time Possible to scan partly by moving the film Possible to scan the entire area although it is not normal method Possible to scan the centre area alone Not...

Страница 41: ...ating or Flipping the index frames Reversing frame order full scale view Saving the index scan image Saving the index image file Loading the index image file FINAL Scan and Save see page 98 Launch the...

Страница 42: ...ct an image for prescanning or scanning There are two options for making an index scan Speed or Quality Select the desired option in the Preference dialog box see page 29 Click on Index tab in the Mai...

Страница 43: ...ar in the Index tab NOTE To cancel the index scan press the escape key Command and period for the Macintosh until the Cancelling Index Scan message box appears The completed index scans will appear in...

Страница 44: ...g the selected file name and numbered chronologically Example File_Name01 File_Name02 File_Name03 CLICK CLICK Not selected Press the control key key for the Macintosh while clicking to select addition...

Страница 45: ...ES Rotate or Flip index frames so they appear in the Index scan tab window with the proper orientation REVERSING THE FRAME ORDER Some cameras are reverse winding so the last frame is exposed at the be...

Страница 46: ...ed file name Windows For Windows the file can be saved in the Windows Bitmap BMP or JPEG format Macintosh For Macintosh the file can be saved in the PICT or JPEG format The index scan images are arran...

Страница 47: ...er the desired file name select the file destination and then click on Save When the index images are displayed these images are saved regardless of the film set in the scanner When the index images a...

Страница 48: ...le The previously displayed preview images are erased 1 Click on in the Main window The standard file open dialog box for each operating system will appear 2 Select the index file to be load and then...

Страница 49: ...ock Auto cropping Cropping the Image Cropping the prescan image Focus Point AF auto focus Focus Manual Displaying frame number RGB CMY information IMAGE CORRECTION see page 63 INDEX SCAN see page 41 F...

Страница 50: ...n the Scan button This ensures that final scan will be the best it can be Click on the Prescan tab in the Main window Rotate Left button Rotate Right button Flip Horizontal button Flip Vertical button...

Страница 51: ...Scan Multi PRO 51 1 Click on in the Main window The prescanned image will appear in the Prescan tab MAKING A PRESCAN NOTE Press Ctrl when prescanning on the Macintosh to see CMY values in the RGB CMY...

Страница 52: ...Click on the and buttons to correct the orientation of your image before scanning Changes will be reflected in the prescan image Click on to rotate the image 90 clockwise Click on to rotate the image...

Страница 53: ...left to right or top to bottom before scanning Changes will be reflected in the prescan image Click on to flip the image top to bottom Click on to flip the image left to right The image is upside dow...

Страница 54: ...In 1 Click on The pointer will change to 2 Click anywhere on the image to zoom in The clicked position will be the centre of the magnified view in the Prescan tab The disappears from the magnifier ico...

Страница 55: ...ged image The grab button can only be selected when the image has been magnified beyond the limits of the Prescan tab SCROLLING THE IMAGE 1 Click on in the Prescan image display area The pointer will...

Страница 56: ...e AUTO EXPOSE FOR SLIDES has been selected in the preferences SETTING THE AE LOCK After prescanning the image 1 Click on cannot be selected until an image has been prescanned 2 Select another image th...

Страница 57: ...anning the image 1 Click on 2 Press the Shift key The AE area is indicated by an unbroken line whereas the cropping area is indicated by a dashed line 3 While pressing down the Shift key change the AE...

Страница 58: ...rame and drag the pointer in or out Click on the corners and drag to resize the cropping frame proportionally Click on the sides and drag to resize the cropping frame non proportionally To move the cr...

Страница 59: ...is prescanned again a more precise prescan image is displayed To define a new cropping frame Click and drag outside the current cropping frame You can resize the cropping frame to cover the full presc...

Страница 60: ...he focus adjustment should be performed again using the point AF or Manual Focus function Automatic autofocus can be turned on and off in the Preferences see page 29 POINT AF This allows you to use au...

Страница 61: ...to be in sharp focus The focus control window dialog box will appear 3 Adjust the slider until the black and white lines are at their longest for maximum sharpness Click and drag the slider to the le...

Страница 62: ...display the previous frame click on RGB CMY INFORMATION The RGB information from the pointer position is always displayed in the Prescan tab The information is described in brightness levels from 0 t...

Страница 63: ...on Selective colour correction Unsharp mask Snapshot Cancelling the image correction Full screen view Job save job load Digital ICE ROC GEM INDEX SCAN see page 41 FINAL Scan and Save see page 98 PREVI...

Страница 64: ...our button Variations button Hue Saturation Lightness Correction button Brightness Contrast Colour Balance Correction button Tone Curves Histogram Correction button Snapshot display area Unsharp Mask...

Страница 65: ...to 255 from left to right side The tone curves and histogram are linked to each other so that when the tone curve is corrected the histogram is automatically corrected Click on in the Image Correction...

Страница 66: ...r to be corrected 3 Click and drag the portion of the curve to be changed The coordinate value of the cursor is displayed from 0 to 255 The correction made by changing the tone curves is applied to th...

Страница 67: ...in each R G and B 2 Input the desired white point value 3 Click on The cursor changes to the white dropper shape 4 Click the desired highlight point of the image The image is corrected so that the poi...

Страница 68: ...ased the histogram returns to the previous one AUTO SETTING When Auto Setting button is clicked the image is corrected automatically by removing parts of the histogram which contain no information and...

Страница 69: ...lthough the output slider does not normally need to be adjusted use it according to the characteristics of the output equipment For example use the output slider when the black part is not printed cle...

Страница 70: ...ng of certain colors colour overlap Click on in the Image Correction tab THE BRIGHTNESS CONTRAST AND COLOUR BALANCE CORRECTION DIALOG BOX NAMES OF PARTS Correction Result LUT Look Up Table display Pos...

Страница 71: ...ecome brighter and dark areas become darker RGB colour balance correction By dragging the Colour Balance slider to the right or inputting a big plus number in the text box the contect of each channel...

Страница 72: ...NAMES OF PARTS 1 Drag each Hue Saturation or Lightness slider or input the desired value in the text box The change will be reflected in the prescan image To change the colour move the Hue Saturation...

Страница 73: ...to the rightmost or leftmost side the hue of the image is reversed Saturation correction Dragging the saturation slider to the right or inputting a big plus number in the text box icreases the intensi...

Страница 74: ...are displayed VARIATION CORRECTION A number of images showing different variations are displayed around the currently corrected prescan image You can correct the image while comparing with the variat...

Страница 75: ...h direction 3 Correct the image properly by repeating the operation in step 2 BRIGHTNESS CONTRAST CORRECTION Eight images in which brightness and contrast have been corrected by one step in each direc...

Страница 76: ...the right side shows increased saturation 1 Click the image in the direction you want to correct except for the image in the centre The image you clicked is placed in the centre and 2 new variation im...

Страница 77: ...lue instead of purplish decrease the component amount of Magenta from Blue to obtain a very blue sky Click on in the Image Correction tab THE SELECTIVE COLOUR CORRECTION DIALOG BOX NAMES OF PARTS SELE...

Страница 78: ...level can be input respectively The change will not be reflected in the prescan image UNSHARP MASK Unsharp Mask can increase definition of the image to make it clearer It is useful if the image is sl...

Страница 79: ...rpening effect is extended around each pixel Normally we recommend 1 to 2 for highly processed print images This alteration cannot be recognized much on a print as it will be on the screen Threshold l...

Страница 80: ...orarily while processing or when correcting the image again after going back to a certain step STORING IN THE SNAPSHOT DISPLAY AREA TEMPORARILY 1 Click on in the Image Correction tab The displayed pre...

Страница 81: ...rent image correction is cancelled and the image returns to the previous one REDO THE CORRECTION When is clicked the cancelled image correction can be resumed DELETE THE IMAGE CORRECTION When in the I...

Страница 82: ...w CHECKING THE CORRECTION RESULT WHILE LINING UP IMAGES When is clicked the Image correction tab is divided into right and left sides the pre correction image is displayed on the left side and post co...

Страница 83: ...correct the image by loading the most appropriate previously saved correction job SAVING AN IMAGE CORRECTION JOB 1 Click on in the Image Correction tab The Register Image Correction Job dialog box is...

Страница 84: ...d the saved correction job and apply an image correction to the displayed image 1 Click on in the Image Correction tab The Selected Image Correction Job dialog box is displayed 2 Select the Image Corr...

Страница 85: ...space 512MB 512MB 512MB 2GB 4GB 6GB 35mm Multi Format 35mm Multi Format 6x9 Minimum system requirements CPU Pentium 166MHz later Pentium 166MHz later Pentium 166MHz later Memory Hard disk space 256MB...

Страница 86: ...rements CPU Power PC G4 later Power PC G4 later Power PC G4 later Memory Hard disk space 384MB 384MB 384MB 2GB 4GB 6GB 35mm Multi Format 35mm Multi Format 6x9 Minimum system requirements CPU Power PC6...

Страница 87: ...u can use the Digital ICE function for the following types of B W film only after the film has been developed in colour and scanned with the Colour Negative setting for the film type We cannot assure...

Страница 88: ...for Slides in the Preferences the colour matching the AE Lock function when prescanning see page 56 or the AE Area Lock function see page 57 are cancelled When using the Digital ROC function be sure...

Страница 89: ...o 100 can be input The bigger the value is the more effective the correction result is Digital GEM text box Digital GEM slider Digital GEM image display area Confirm Digital GEM effect area Confirm Di...

Страница 90: ...d scanned with the Colour Negative setting for the film type We cannot assure this procedure for other types of film Kodak Select Black White 400 Kodak T400CN Illford XP2 Super 6 Change the Confirm Di...

Страница 91: ...DiMAGE Scan Multi PRO 91 FINAL SCAN F L O W SCAN SETTING Creating a job Deleting a job Job type CUSTOM WIZARD FINAL SCAN...

Страница 92: ...or you can directly enter them into the Main window Index tab or Prescan tab THE SCAN SETTINGS PART WINDOW NAMES OF PARTS Job Name list box Input Resolution list box Output Resolution list box Input S...

Страница 93: ...handle The driver software automatically determines the input resolution necessary to obtain the desired output size and resolution 1 Click on in the Scan settings part of the window 2 Select the appr...

Страница 94: ...ntered directly or by resizing the cropping frame The values will change if a different unit of measurement is selected The scanning area size can t be changed if the Input Size is locked 6 Enter the...

Страница 95: ...y then click on The scan settings you specified are registered with the specified name as a job file The Job Registry dialog box will disappear Input the job name within 24 characters DELETING A JOB I...

Страница 96: ...ob file Should these settings be changed the new settings can be saved to another job file All Job files are collected within the Job File List that designates 10 individual categories for each image...

Страница 97: ...re are 11 paper size options Ink Jet Dye Sub Printer Ink Jet and Dye sublimation printers Uses an output resolution of 300 dpi There are 10 paper size options Photo CD Uses an output resolution of 300...

Страница 98: ...e final scan will appear in the host applications window 2 Save the image using the instructions for your host application 3 Close the Control Window to exit the DiMAGE Scan Multi PRO driver software...

Страница 99: ...t With Macintosh a PICT file which width is more than 4096 pixel cannot be selected 4 Click on The final scan will begin When scanning is complete the scan will be saved in the selected location The s...

Страница 100: ...t to the Film Format drop down list to display the film format and select the appropriate film format When selecting 6x4 5 6x6 6x7 6x8 or 6x9 in the film format select the type of the holder set in th...

Страница 101: ...pose for Slides Auto Focus at Scan Colour depth or Multi Sample Scan see SETTING THE PREFERENCES on page 29 For details of Colour Matching see COLOUR MATCHING on page 106 4 Set each item and click on...

Страница 102: ...tings see SCAN SETTINGS window on page 92 6 Set the resolution and size of the image to be scanned and click on The Image Correction window is displayed CUSTOM WIZARD The image correction can be perfo...

Страница 103: ...he Custom Wizard Setting window 8 Click on The Scanning is Complete window is displayed CUSTOM WIZARD The scanning starts while the setting window is displayed and will change to the scanning complete...

Страница 104: ...ated easily by calling up the registered setting by the Custom Wizard 1 Place the film holder that you are going to scan on the scanner 2 Click on on the main window of Custom Wizard The Custom Wizard...

Страница 105: ...DiMAGE Scan Multi PRO 105 A P P E N D I X SCAN JOB FILE LIST GLOSSARY TROUBLE SHOOTING USER TECHNICAL SUPPORT SPECIFICATIONS IEEE 1394 INTERFACE COLOUR MATCHING...

Страница 106: ...sfering data do not unplug or connect the IEEE1394 cable To disconnect the IEEE1394 Interface unit For Windows 2000 Professional 1 Close the driver software 2 Confirm that the indicator lamp is not bl...

Страница 107: ...ecified colour space such as sRGB or by using the ICC profile a file that states the characteristics of the monitor s colour reproduction to reproduce an image suitable for your monitor You can make t...

Страница 108: ...ist box The available output colour space settings are displayed 3 Click the desired output colour space setting ICC PROFILE SETTING 1 Insert a check mark in the Use monitor ICC profile checkbox 2 Cli...

Страница 109: ...play function 1 such as the Adobe Photoshop Ver 5 to 6 is being used with the Monitor Correction Display function ON Output Colour Space Optional output colour space can be selected select the same co...

Страница 110: ...PP 2 21 3RVW DUG LQFK 2 21 QN HW 6XSHU PP 2 21 H 6XE3ULQWHU XOO PP 2 21 XOO PP 2 21 DOI PP 2 21 4XDUWHU PP 2 21 HWWHU XOO LQFK 2 21 HWWHU DOI LQFK 2 21 HWWHU4XDWHU LQFK 2 21 3KRWR PP 2 21 3KRWR PP 2 2...

Страница 111: ...DiMAGE Scan Multi PRO 111 SCAN JOB FILE LIST 35 mm...

Страница 112: ...LQFK 2 21 PP 2 21 PP 2 21 PP 2 21 3RVW DUG LQFK 2 21 QN HW 6XSHU PP 2 21 H 6XE3ULQWHU XOO PP 2 21 XOO PP 2 21 DOI PP 2 21 4XDUWHU PP 2 21 HWWHU XOO LQFK 2 21 HWWHU DOI LQFK 2 21 HWWHU4XDWHU LQFK 2 21...

Страница 113: ...DiMAGE Scan Multi PRO 113 SCAN JOB FILE LIST 120 220 6x4 5...

Страница 114: ...2 21 PP 2 21 PP 2 21 PP 2 21 PP 2 21 3RVW DUG LQFK 2 21 QN HW 6XSHU PP 2 21 H 6XE3ULQWHU XOO PP 2 21 XOO PP 2 21 DOI PP 2 21 4XDUWHU PP 2 21 HWWHU XOO LQFK 2 21 HWWHU DOI LQFK 2 21 HWWHU4XDWHU LQFK 2...

Страница 115: ...DiMAGE Scan Multi PRO 115 SCAN JOB FILE LIST 120 220 6x6...

Страница 116: ...2 21 PP 2 21 PP 2 21 PP 2 21 PP 2 21 3RVW DUG LQFK 2 21 QN HW 6XSHU PP 2 21 H 6XE3ULQWHU XOO PP 2 21 XOO PP 2 21 DOI PP 2 21 4XDUWHU PP 2 21 HWWHU XOO LQFK 2 21 HWWHU DOI LQFK 2 21 HWWHU4XDWHU LQFK 2...

Страница 117: ...DiMAGE Scan Multi PRO 117 SCAN JOB FILE LIST 120 220 6x7...

Страница 118: ...2 21 PP 2 21 PP 2 21 PP 2 21 PP 2 21 3RVW DUG LQFK 2 21 QN HW 6XSHU PP 2 21 H 6XE3ULQWHU XOO PP 2 21 XOO PP 2 21 DOI PP 2 21 4XDUWHU PP 2 21 HWWHU XOO LQFK 2 21 HWWHU DOI LQFK 2 21 HWWHU4XDWHU LQFK 2...

Страница 119: ...DiMAGE Scan Multi PRO 119 SCAN JOB FILE LIST 120 220 6x8...

Страница 120: ...2 21 PP 2 21 PP 2 21 PP 2 21 PP 2 21 3RVW DUG LQFK 2 21 QN HW 6XSHU PP 2 21 H 6XE3ULQWHU XOO PP 2 21 XOO PP 2 21 DOI PP 2 21 4XDUWHU PP 2 21 HWWHU XOO LQFK 2 21 HWWHU DOI LQFK 2 21 HWWHU4XDWHU LQFK 2...

Страница 121: ...DiMAGE Scan Multi PRO 121 SCAN JOB FILE LIST 120 220 6x9...

Страница 122: ...122 SCAN JOB FILE LIST MULTI FORMAT 35 mm DWHJRU RE QDPH QSXW 5HV 2XWSXW 5HV 0DJ 8QLW QSXW 6L H RFN 1 2XWSXW 6L H RFN 287 QSXW HIDXOW HIDXOW SL HO 2 2...

Страница 123: ...DiMAGE Scan Multi PRO 123 SCAN JOB FILE LIST MULTI FORMAT 35 mm...

Страница 124: ...when resampling up JPEG The JPEG Joint Photographic Experts Group compression standard is capable of producing a high compression ratio while maintaining image quality JPEG is a widely supported imag...

Страница 125: ...merican National Standards Institute SCSI 3 refers to many variations including a parallel interface SHADOWS The dark areas of an image TIFF Tagged Image File Format TIFF files contain bit mapped data...

Страница 126: ...type Could not recognise the film type Set the film type manually Insufficient Memory Increase the memory requirements for the host application If you have scanned multiple images close and relaunch t...

Страница 127: ...e have the following information ready when calling Minolta Technical Support Make and Model of your computer Available application RAM Operating System version Other connected SCSI or IEEE1394 device...

Страница 128: ...c range 4 2 tested value Light Source 3 Wavelength Cold Cathode Fluorescent Image Sensor RGB 3 line CCD 7 260 pixels 1line Focus Auto focus Manual focus Interface Ultra SCSI D sub half pitch 50p x2 an...

Страница 129: ...AGE Scan Multi PRO 129 Index Scan Windows 35mm Color Positive 6 frames 30 s Vorscan 9 s Scan 45 s Prescan Windows 120 220 6x9 Color Positive 13 sec Scan 3 min 50 sec Index scan Macintosh 35mm Color Po...

Отзывы: