49
Settings Section
2. About the Target Color
The target color is the reference used to measure how much the measured values are deviated from a certain color.
The target color can be set for each probe of each memory channel.
The target color is set when the following is performed.
1
User calibration (page 51) ....................... Performing user calibration sets the calibration values as the target
color.
2
Setting/changing the target color ............. Set or change the target color in the following cases.
(page 62)
•
When you want to set the target color for memory channel CH00
•
When you want to set a color that differs from the color used for user
calibration as the target color to a user-calibrated memory channel
•
When you want to perform measurement using Minolta’s calibra-
tion standard without user calibration and want to use the analog
display function
3
Inputting the RGB emission .................... When you select analyzer measurement mode and input the RGB
characteristic for analyzer mode
emission characteristic for analyzer mode, also set the target color
(page 59)
(W).
●
Since when calibration factor is input for user calibration/analyzer mode the target color is also set at the same
time, the previously set target color will be deleted.
●
To change the currently set target color, change it as explained in “Setting/Changing the Target Color” (page
62). Even if the target color is changed, the currently set correction factor for user calibration and the RGB
emission characteristic for display’s analyzer mode will remain unchanged.
In the case of the same memory channels, the tar-
get color is stored in their common memory irre-
spective of measurement mode.
As a result, the target color set last will be stored
irrespective of how it was set.
Values that can be set to one memory channel
* The target color is common irrespective of color space mode.
Matrix calibration
Used for xyLv, T
∆
uvLv, u'v'Lv or
XYZ measurement mode
Correction factor
for user calibration
Target color *
Display’s emission
characteristic
Used for analyzer mode
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание CA-100PLUS -
Страница 25: ...22 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 47: ...44 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 101: ...98 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 123: ...120 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 124: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...