miniDSP Ltd, Hong Kong /
www.minidsp.com
/ Features and specifications subject to change without prior notice
45
To save the currently selected configuration to a file, drop down the File menu, then select
Save
and then
Save
current configuration
. In the file box, select a location and name of the file, and save it.
To load a configuration, first select the configuration preset that you wish to load the parameters into. Then
drop down the File menu, select
Load
, and then
Load configuration to current slot
.
If the plugin is online, the new configuration data will be downloaded to the DDRC-88D immediately. If the
plugin is offline, the data will be loaded into the user interface only, and will be downloaded to the DDRC-88D
the next time it is synchronized.
To copy a configuration from one preset to another, simply save the configuration to a file, then
select a different preset and load the file.
A stored configuration contains the data for the DDRC-88BM plugin
only
. It does not contain a Dirac
Live filter set. To change the Dirac Live filters, use the
Export
tab of the
Dirac Live Calibration Tool
for miniDSP
.
8.4.5
Relationship with Dirac Live
Each configuration preset in the DDRC-88BM plugin corresponds to the same-numbered filter set configured in
Dirac Live Calibration Tool. For example, if the remote control or front panel is used to select preset 3, then both
DDRC-88BM configuration 3 and Dirac Live filter set 3 are loaded for audio processing.
The stored configuration file contains the data for the DDRC-88BM plugin only. The Dirac Live filters must be
loaded separately using
Dirac Live Calibration Tool for miniDSP
.
8.4.6
Restoring to defaults
Configurations can be reset to the factory defaults from the
Restore
menu. There are two options:
Factory Default
Reset all four configuration presets to the factory default settings.
Current Configuration Only
Reset only the currently selected configuration preset to the factory default settings.
If the plugin is online, the configuration data on the processor (all or just one configuration, as selected) will also
be reset to factory defaults. Otherwise,
t
he reset will take place in the user interface only, and the new
configuration data will be downloaded to the processor next time it is synchronized.