①
Net value (4 stations)
Area for displaying the net value.
Data type
: 32 bit binary with sign
Setting range : -99999 ~ 99999
②
Gross value (4 stations)
Area for displaying the gross value.
Data type
: 32 bit binary with sign
Setting range : -99999 ~ 99999
③
Error code (4 stations, 2 stations, 1 station)
Area for displaying the error generating in the main body of CSD-892-73.
Refer to [
④
Error assistance code] for the contents of error code.
Data type
: 16 bit binary
Setting range : 0 ~ 255
④
Error assistance code (4 stations, 2 stations, 1 station)
Area for displaying the error generating in the main body of CSD-892-73.
Data type
: 16 bit binary
Setting range : 0 ~ 255
Error code
Error assistance code
Contents
0
0
1
Weighing sequence
error
Unde
fi
ned
Unde
fi
ned
2
(ZERO set error)
1
ZERO set error
In case of execute ZERO out of range of zero.
2
Tare weight cancellation error
In case of execute tare weight cancellation under the
condition of being not able to execute it.
3
(Other error)
3
A/D conversion error
31
EEPROM writing error.
32
EEPROM reading error.
99
Except for the measurement mode.
4
(Calibration error)
0
TE-L error
1
TE-H error
2
SP-L error
3
SP-H error
99
(Setting Error)
0
Receiving unde
fi
ned command
When unde
fi
ned data is set at command No.
1
Error outside setting range
2
Error that cannot be executed.
•
Please refer to [19. Error display] for the contents of error code.
88
C
C
-Li
nk