In CSD-892-73, each data is stored in internal RAM and EEPROM as follows.
The data in EEPROM can be stored almost permanent due to nonvolatile.
12-1. Data stored in internal RAM
•
Tare weight cancellation (Saving to EEPROM is also possible.)
•
ZERO set data (Saving to EEPROM is also possible.)
•
ZERO tracking data
12-2. Data stored in EEPROM
•
Calibration data
•
Function data
•
C function data
•
S function data
•
Digital linearize data
•
Set data of simple comparison data (FINAL, FREE FALL, PRELIMINARY 1,
PRELIMINARY 2, OVER, UNDER, NEAR ZERO, FULL)
•
Set data of 5-steps comparator mode (S0, S1, S2, S3, S4, NEAR ZERO and FULL)
12-3. Data that stored place can be changed
•
ZERO set data
•
Tare weight cancellation data
The above-mentioned data can select the preservation place from [Internal RAM] or
[EEPROM].
The stored place of data is set by the setting of C function CF-17.
Please refer to [6-10. Change of data stored place].
Default has set to [Internal RAM] for both data.
12. Stored data of setting data
•
Please do not change in the set value under the measurement because the A/D
sampling rate decreases temporarily while writing data to EEPROM.
•
The data stored in internal RAM is not backed up.
•
Please set the stored place to [Internal RAM] when the set data is continuously
changed, and the rewritable time of [EEPROM] might exceed about one million
times.
•
Please do not change in the set value under the measurement because the A/
D sampling rate decreases temporarily while rewriting the set value when the
stored place of set data is [EEPROM]. Please set the stored place to Internal
[RAM] if you change the set value under the measurement. Please refer to [6-10.
Change of data stored place] for the details of setting method of stored place.