
⑥
Reading out ROM version (Host
→
CSD-892-73)
2
4
6
@
0
0
4
5
Terminator
In normal operation
Return (CSD-892-73
→
Host)
2
4
6
8
10
12
14
@
0
0
4
5
v
Terminator
⑦
Reading out the condition 2 (Host
→
CSD-892-73)
2
4
6
@
0
0
5
0
Terminator
In normal operation
Return (CSD-892-73
→
Host)
2
4
6
@
0
0
5
0
Terminator
In abnormal operation
Return (CSD-892-73
→
Host)
2
4
6
8
@
0
0
E
R
0
2
Terminator
Command No.
Operation
40
Reading out ROM version
Command No.
ROM version
Command No.
Operation
50
Display Gross value
51
Display Net value
52
ZERO
53
ZERO clear
54
Tare weight cancellation
55
Tare weight cancellation clear
5I
Error cancellation
The condition of error transmission is as follows
:
•
When we cannot execute ZERO set outside the effective range in executing the
command No. 52 for ZERO set.
•
When we cannot proceed tare weight cancellation with the display of [
±
OL] in
executing the command No. 54 for tare weight cancellation.
Command No.
Command No.
Command No.
117
U
S
B
(R
S
-2
32
C
)