3-11
1
2
3
4
5
6
Chapter 3 Setup
5
Press the
key, and press
to select the type of auto cleaning.
•
There are “DEFAULT”, “PAGE”, “LENGTH” and
“TIME” for auto cleaning.
DEFAULT
: When the set cleaning timing has
been reached, the machine performs
head cleaning automatically.
FILE
: When the set number of prints has
been completed, the machine
performs head cleaning
automatically.
LENGTH
: When the set length has passed, the
machine performs head cleaning
automatically.
TIME
: When the set time has passed, the
machine performs head cleaning
automatically.
• If you have selected “DEFAULT”, proceed to Step 8.
6
Press
, and press
to
select the cleaning interval.
• Depending on the auto cleaning type selected in
the Step 3, the setting value differs.
For FILE
: 1 to 1000 file
For LENGTH
: 0.1 to 100.0m (in 0.1m increment)
For TIME
: 10 to 480min (in 10min increment)
7
Press the
key, and press
to select the cleaning type.
•
Set Value
: NORMAL/ SOFT/HARD
8
Press the
key, and press
to select “Cleaning Check”.
9
Press the
key, and press
to select set value.
•
Set Value
: ON/ OFF
• If you have selected “FILE” st step 5, proceed to
Step 12.
10
Press the
key, and press
to select “EXEC.TIMING”.
11
Press the
key, and press
to select set value.
• There are “END OF FILE” and “PRINTING” for set
values.
END OF FILE
: Carries out the cleaning
operations between files after the
cleaning interval configured
under “LENGTH” or “TIME” in
Step 6 has passed.
PRINTING
: Stops printing and starts the
cleaning operation immediately
after the cleaning interval
configured under “LENGTH” or
“TIME” in Step 6 has passed.
12
Press the
key .
13
Press the
key several times to
end the setting.
Setting Interval wiping
When the set time has passed, nozzle face of the head is
cleaned automatically to remove ink droplets on the
nozzle face.
In case that deflection, nozzle missing, or symptom which
ink droplets fall down occurred, set the interval between
each operation shorter.
1
Press
(MENU)
in LOCAL.
2
Press
to
select
SETUP 1 to 4,
and press the
key.
• SETUP MENU will be displayed.
3
Press
(<<)
.
4
Press
to select “INTERVAL
WIPING”, and press the
key.
5
Press
to set intervals.
• Set Value : 3 to 255 Minutes, OFF
• When [OFF] is set, periodical wiping is not
executed.
6
Press the
key.
7
Press the
key several times to
end the setting.
• Depending on the state of the heads, etc., the image
quality deterioration may not be improved even with
this function performed.In this case, contact our
service office or the distributor in your region.
Содержание tx300p
Страница 12: ...xi Warning labels No Reorder Label 1 M910931 2 M907833 3 M903330 4 M907935 5 M905811 ...
Страница 14: ...xiii Warning labels ...
Страница 58: ...2 28 Chapter 2 Basic Operation ...
Страница 86: ...Chapter 3 Confirming Machine Informationa 3 28 ...
Страница 108: ...Chapter 4 Maintenance 4 22 ...
Страница 122: ...Chapter5 Troubleshooting 5 14 ...
Страница 128: ...Chapter6 Appendix 6 6 ...
Страница 130: ...NU FW 2 20 MIMAKI ENGINEERING CO LTD 2017 ...