3-30
Re-irradiate lamp light on the drawn media
By re-irradiating lamp light on the drawn media, you can cure ink more surely.
Setting method of area for irradiating lamp light
Set the start position and the end position of the lamp light irradiation as below:
1
Adjust the height of the Post Cure Unit depending on the media. (
P.3-19)
• When adjusting height, set the same type media as the one on which you re-irradiate lamp light on the
table.
• If you use the drawn media to adjust the height, there is the danger that the height adjusting jig may
damage the drawing surface.
2
Set the drawn media on which you re-
irradiate lamp light on the table.
• End position of lamp light irradiation is calculated by adding the depth of the Post Cure Unit (190mm)
to the above (A).
• By setting the end position backward by the depth of the Post Cure Unit, you can irradiate lamp light
from the front edge of the image.
Depth of Post Cure
Unit located in front
of Y bar (190mm)
Distance from front side of image
on which you irradiate lamp light
to the drawing origin
Distance from end position
of image on which you
irradiate lamp light to the
drawing origin (A)
Drawing origin
Содержание JFX-1631/1615 Plus
Страница 1: ...MIMAKI ENGINEERING CO LTD URL http eng mimaki co jp D202017 20...
Страница 82: ...3 38...
Страница 122: ...4 40...
Страница 134: ...5 12...
Страница 138: ...6 4...
Страница 152: ...6 18...
Страница 153: ...D202017 20 25122014...
Страница 154: ...SN FW 2 80 MIMAKI ENGINEERING CO LTD 2014...