3-4
Registering the thickness of the media
Register the thickness of loading media.
There are three types of registering; “Register the thickness of the media manually”, “Adjust the gap with the
or
keys”, and “Measuring the thickness of the media automatically”.
Register the thickness of the media manually
1
Press the
key in the local mode.
2
Select the [HEAD HEIGHT] by pressing the
or
key.
3
Press the
key twice.
4
Press the
or
key to enter the thickness of
loading media.
• Set value : 0.0 to 50.0mm
5
Press the
key.
6
Press the
key to end the setting.
Adjust head gap with the
or
keys
1
Press the
or
key.
2
Adjust with pressing the
or
key.
3
Press the
key.
UP
DOWN
F UNC T I ON
V I EW
< EN T >
FUNCTION
F UNC T I ON
H E A D H E I GH T
< EN T >
MED I A T H I CK NE S S
2 . 5 mm
ENTER
MED I A T H I CK NE S S
1 0 . 5 mm
F UNC T I ON
H E A D H E I GH T
< EN T >
ENTER
END
UP
DOWN
OR I G I N S E T UP
Z HE I GH T = 4 5 . 0
UP
DOWN
OR I G I N S E T UP
* * Z HE I GH T * *
UP
DOWN
OR I G I N S E T UP
H E A D GA P = 1 . 2
ENTER
Содержание JFX-1631/1615 Plus
Страница 1: ...MIMAKI ENGINEERING CO LTD URL http eng mimaki co jp D202017 20...
Страница 82: ...3 38...
Страница 122: ...4 40...
Страница 134: ...5 12...
Страница 138: ...6 4...
Страница 152: ...6 18...
Страница 153: ...D202017 20 25122014...
Страница 154: ...SN FW 2 80 MIMAKI ENGINEERING CO LTD 2014...