– 3.20 –
Correct the light pointer position [MARK SENSOR]
In case fails to recognize a registration mark, adjust the light pointer position.
Setting Procedure
1) Attach a roller ball pen [for a plotter use] on
the tool holder.
*
Be sure to use the applied pen for the pen
adapter(not marketed pens).
2) Confirm the plotter is in the local mode.
3) Push [FUNCTION] key.
4) Select [MARK SENSOR] by pushing jog keys,
[ ] [ ].
5) Push [ENTER/HOLD] key.
6) Select [POINTER OFS] by pushing jog keys,
[ ] [ ].
7) Push [ENTER/HOLD] key.
The light pointer on, and moves to a center of a crisscross
pattern to plot a 10mm-by-10mm crisscross pattern.
8) Adjust the light pointer position to match both
center of the light pointer and the crisscross
pattern.
9) Push [ENTER/HOLD] key.
Return to the local mode after registered the adjustment
position.
*
The value registered in the [POINTER OFS]
cannot initialize even if executing the [SETUP
RESET].
SQUARE CUT <ENT>
MARK sensor <ENT>
SENSOR CHK <ent>
A = -3.9 B = -6.0
CT1 020 050 0.30
CT1 020 050 0.30
FUNCTION
SENSOR OFS <ent>
Содержание CG-FX SERIES