Chapter 4 Maintenance
4-20
2
Press
to select “MAINTENANCE”,
and press the
key.
• MAINTENANCE MENU will be displayed.
3
Press
, and press the
key.
• Carriage will move to the left end of this machine.
4
Press the
key.
• “STATION” will be selecte
5
Open the right maintenance cover.
6
Take out the nozzle cap.
• Hold the nozzle cap and pull it out.
7
Insert the new wiper.
• Insert the nozzle cap so that its protrusion is in the
nozzle opening.
8
Close the maintenance cover, and press
the
key.
• After its initial operation, the machine returns to
LOCAL.
• Insert it all the way in so that there are no gaps.
Maintenance cover
nozzle cap
protrusion
nozzle opening
No Good
OK
• If the nozzle opening sinks down and is difficult to
insert, support the tube from below by hand.
Содержание 3042 MkII EX
Страница 1: ...MIMAKI ENGINEERING CO LTD https mimaki com D203043 42 Original instructions ...
Страница 16: ...Position of the warning label xv ...
Страница 36: ...Chapter 1 Before Use 1 20 ...
Страница 79: ...4 3 1 2 2 4 5 6 Chapter 4 Maintenance ...
Страница 104: ...Chapter 4 Maintenance 4 28 ...
Страница 116: ...5 12 Chapter 5 Troubleshooting ...
Страница 122: ...Chapter6 Appendix 6 6 ...
Страница 124: ...Chapter6 Appendix 6 8 ...
Страница 126: ... MIMAKI ENGINEERING CO LTD 2016 KW ...