Chapter 1 Before Use
1-12
Removing USB memory
If a USB memory module is inserted in the personal
computer to which a this machine machine is
connected, click "Stop" in the "Safely Remove
Hardware" window by following the instructions given
there first and then remove the module.
Leaving a USB memory module inserted can cause
[ERROR 10 COMMAND ERROR].
Copy the data onto the hard disk before outputting it
for printing.
Connecting the LAN cable
When connecting LAN cable, be sure to follow the note
below:
Printing Via a Network
If printing via a network, you need to configure your
network with the following environment.
If you configure it with an inappropriate environment, it
could cause printing to stop.
• Use LAN cables that are category 6 or higher.
• Use a switching hub and PC that support 1000BASE-T.
If the PC or device connected to the printer is not
1000BASE-T, you cannot perform printing.
After connecting, check the following.
(1)
Check the printer screen display.
• On the local screen or the media detection screen, press
the [Enter] key several times to display the information
screen.
(2)
Check the green light of the LAN connector.
• After turning on the machine, the lamp for the LAN
connector will light up as follows.
Connecting the power cable
About ink bottle
There are 8 ink bottles (6 bottles for 3042 MkII/3042 MkII
e) on the left side of the machine.
Kinds of ink that can be used
• Surely insert LAN cable until clicking noise
sounds.
• Do not plug in or unplug any cable during data
transferring.
• Set the PC sending the print data and the printer
to the same network.
• You cannot connect via a router.
If connecting directly to the printer
Color
Lit?
Condition
Green
ON
Connected with 1000BASE-T
OFF
Connected without 1000BASE-T
Yellow
ON
Link-up
Blinking
Receiving data
OFF
Link-down
• If the yellow light only lights up, or is blinking, the
status is not 1000Mbps. Check the specifications
of the PC, device, and cables.
• Use only the supplied power cable.
• Be sure to connect the power cable plug to the
grounded outlet, or it may cause fire or electric
shock.
• Take care not to damage, break or work upon the
power cable. Or if putting a heavy thing on,
heating, or pulling the power cable, the power
cable can break to cause fire or electric shocks.
Switching hub
If connecting via a switching hub
Содержание 3042 MkII EX
Страница 1: ...MIMAKI ENGINEERING CO LTD https mimaki com D203043 42 Original instructions ...
Страница 16: ...Position of the warning label xv ...
Страница 36: ...Chapter 1 Before Use 1 20 ...
Страница 79: ...4 3 1 2 2 4 5 6 Chapter 4 Maintenance ...
Страница 104: ...Chapter 4 Maintenance 4 28 ...
Страница 116: ...5 12 Chapter 5 Troubleshooting ...
Страница 122: ...Chapter6 Appendix 6 6 ...
Страница 124: ...Chapter6 Appendix 6 8 ...
Страница 126: ... MIMAKI ENGINEERING CO LTD 2016 KW ...