Chapter 5 Troubleshooting
5-8
ERROR 1de
SLIDER PCB V1R2
An error occurred in the power supply of the
slider T PCB.
• Turn off the power on the machine and
turn it on after a while.
• When displaying again,
contact your
local distributor, our sales office, or
service center.
ERROR 1e0
SLIDER PCB V3R3
ERROR 1e2
SLIDER PCB V48
ERROR 1e6
PRAM SIZE SHORTAGE
Memory size shortage.
ERROR 201
COMMAND ERROR
The received data is not print data.
Or, an error occurred in the sent print data.
• Execute data clear and send data again.
• Turn off the power and then on again,
and send data again.
• Check the USB cable connection.
• Use a USB cable conforming to the
standard.
ERROR 202
PARAMETER ERROR
An error occurred in the sent print data.
ERROR 206
PRINTING MODE
Print data with unprintable conditions was
received.
• Check the print data output conditions for
RIP software.
• Check the profile.
• When displaying again,
contact your
local distributor, our sales office, or
service center.
ERROR 304
USB INIT ERR
An error occurred in the USB
communication.
• Check the USB cable connection.
• Reconnect the USB cable.
• Turn off the power and then on again,
and send data again.
• Use a USB cable conforming to the
standard.
ERROR 305
USB TIME OUT
ERROR 401
MOTOR X
An excessive load was applied to the X
motor.
• Check whether the media is set properly
(whether feeding is performed properly).
• Open the cover and check for any
matters that hinder the carriage
operation.
• Turn off the power on the machine and
turn it on after a while.
• When displaying again,contact your local
distributor, our sales office, or service
center.
ERROR 402
MOTOR Y
An excessive load was applied to the Y
motor.
ERROR 403
X CURRENT
An error due to an excessive current of the
X motor was detected.
ERROR 404
Y CURRENT
An error due to an excessive current of the
Y motor was detected.
ERROR 50a
Y ORIGIN
Y Origin was not detected correctly.
• Turn off the power on the machine and
turn it on after a while.
• When displaying again, contact your local
distributor, our sales office, or service
center.
ERROR 50f
L-SCALE BLACK
Abnormal linear scale.
ERROR 511
Z ORIGIN
Z Origin was not detected correctly.
ERROR 519
NEGATIVE P.SENSOR
The negative pressure sensor error was
detected.
ERROR 51a
POSITIVE P.SENSOR
The positive pressure sensor error was
detected.
ERROR 525
WRONG IONIZER
Either the internal circuit has broken or
abnormal discharge occurs.
ERROR 526
IONIZER ION LEVEL
Due to blot on the electrode probe and wear
of it, ion production has decreased.
Use this as a guide for time to take care of
the electrode probe.
• Please clean the electrode probe refer-
ring to the ionizer manual.
• If the status cannot be improved, replace
the relevant electrode probe.
ERROR 527
IONIZER CONDITION
When the ion is absorbed by the
surrounding metal, the instability of
installation environment (temperature,
humidity, peripheral metals, etc.) affects the
performance to remove electricity.
• Please make sure there is no conductor
or another static eliminator in the vicinity
of the ionizer.
• If there is such material, please keep
away from such conductor or another
static eliminator.
Message
Cause
Solution
Содержание 3042 MkII EX
Страница 1: ...MIMAKI ENGINEERING CO LTD https mimaki com D203043 42 Original instructions ...
Страница 16: ...Position of the warning label xv ...
Страница 36: ...Chapter 1 Before Use 1 20 ...
Страница 79: ...4 3 1 2 2 4 5 6 Chapter 4 Maintenance ...
Страница 104: ...Chapter 4 Maintenance 4 28 ...
Страница 116: ...5 12 Chapter 5 Troubleshooting ...
Страница 122: ...Chapter6 Appendix 6 6 ...
Страница 124: ...Chapter6 Appendix 6 8 ...
Страница 126: ... MIMAKI ENGINEERING CO LTD 2016 KW ...