IMPORTANT SAFETY INSTRUCTIONS

WARNING  

READ ALL SAFETY WARNINGS AND INSTRUCTIONS. 

Failure to follow 

         the warnings and instructions may result in electric shock, fi re and/or serious injury. 
Save these instructions - 
This operator’s manual contains important safety and operating 
instructions for the MILWAUKEE
 M12 Sub-Scanner™ Detection Tool. Before using the Sub-
Scanner,  read this operator’s manual, your battery pack and charger operator’s manual, and 
all labels on the battery pack, charger and Sub-Scanner.

FUNCTIONAL DESCRIPTION 

PERSONAL SAFETY

WORK AREA SAFETY

SYMBOLOGY

• Avoid dangerous environments

. Do not use in 

rain, snow, damp or wet locations.

 

Do not use in 

the presence of explosive atmospheres (gaseous 

fumes, dust or 

fl

 ammable materials) because 

sparks may be generated when inserting or remov-

ing battery pack, possibly causing 

fi

 re. 

• Stay alert, watch what you are doing and use 

common sense when operating the Sub-Scan-
ner. Do not use while you are tired or under 
the infl uence of drugs, alcohol or medication. 

A moment of inattention may result in serious 

personal injury.

• Do not overreach. Keep proper footing and 

balance at all times.

 This enables better control 

in unexpected situations.

BATTERY USE AND CARE

SERVICE

• Recharge only with the charger specifi ed by 

the manufacturer. 

A charger that is suitable for 

one type of battery pack may create a risk of 

fi

 re 

when used with another battery pack.

• Use power tools only with specifi cally desig-

nated battery packs. 

Use of any other battery 

packs may create a risk of injury and 

fi

 re.

• When battery pack is not in use, keep it away 

from other metal objects like paper clips, 
coins, keys, nails, screws, or other small metal 
objects that can make a connection from one 
terminal to another. 

Shorting the battery termi-

nals together may cause burns or a 

fi

 re.

• Under abusive conditions, liquid may be eject-

ed from the battery, avoid contact. If contact 
accidentally occurs, fl ush with water. If liquid 
contacts eyes, additionally seek medical help. 

Liquid ejected from the battery may cause irritation 

or burns.

ASSEMBLY

WARNING 

Recharge only with the

   

 charger specified for the battery. 

For specifi c charging instructions, read the 
operator’s manual supplied with your charger 
and battery.

Direct Current

Federal Communications 
Commission

Read Operator’s Manual

Inserting/Removing the Battery

To 

remove 

the battery, push in the release buttons 

and pull the battery pack away from the tool.

To 

insert

 the battery, slide the pack into the body of 

the tool. Make sure it latches securely into place.

 

OPERATION

WARNING 

Always remove battery

   

 pack before changing or removing 

accessories. Only use accessories specifi -
cally recommended for this tool. Others may 
be hazardous.

On/Off

Press the   button to turn the tool on and off.

Sleep Mode

The Sub-Scanner is automatically powered off in 

about 20 minutes after the last operation. To reset, 

press any button. If the display is blank when the 

Sub-Scanner is turned ON, charge the battery ac-

cording to the battery/charger manual.

The Sub-Scanner does use battery power in sleep 

mode. Be sure to turn OFF the tool to conserve 

battery power.

Set-up

1.Turn on the Sub-Scanner (defaults to Metal mode 

without sound).  

2.Press the MENU button.

3.Use the up   and down   buttons to scroll 

through the menu items (UNITS, SOUND).  Use 

the Calibrate button to select. 

  UNITS - Select either English or Metric units.

  SOUND - Turn sound On or Off

4.Press the MENU button again to exit.

Selecting Mode

1.Turn on the Sub-Scanner.  

2.Metal mode is the default scan setting.

3.To change between Metal and Stud, select the 

METAL and STUD buttons.

METAL Mode 

In metal mode, the Sub-Scanner will detect both 

ferrous (>14 mm Ø) and non-ferrous (>16 mm Ø) 

metals in concrete up to a depth of 6". The Sub-

Scanner can not reliably detect metal behind mate-

rial of varying densities. Materials such as carpet, 

wire metal mesh backing, damp walls, and stucco 

may affect readings. Alternating surfaces, such 

as thick grout lines or extremely heavy plaster on 

drywall, may be detected or show as metal or studs.

1.Turn on the Sub-Scanner.  

2.Select Metal mode (default).

3.Standard depth of 

scan (up to 4" deep 

scan) is defaulted. 

Press the Metal 

button to switch 

to Deep depth of 

scan (up to 6" deep 

scan).

 

NOTE:

 Deep mode scans may display more 

"noise" due to the higher sensitivity of the scan. 

4.Hold the Sub-Scanner 

against

 the surface and 

press the Calibrate button. 

5.The Sub-Scanner 

must remain flat 

against and in con-

tact with surface 

during entire scan. 

 If CALIBRATION 

E R R O R   i s   d i s -

played, the tool was 

placed in an area 

where metal is pres-

ent. Move the Sub-

Scanner to another 

position and restart 

calibration.

6.When SCANNING is displayed, move the Sub-

Scanner across the surface. Keep your free hand 

and other objects at least 6” (152 mm) away to 

avoid false readings.

7.When metal is detected, the type (ferrous or non-

ferrous) and depth 

are displayed. Con-

tinue to move the 

Sub-Scanner across 

the surface. As you 

approach metal, 

the distance will de-

crease. As you move 

away from the met-

al, the distance will 

increase. When the 

minimum distance 

and indicator arrow 

are displayed, the 

Sub-Scanner is di-

rectly over the metal 

at that distance. The 

minimum distance and indicator arrow may ap-

pear for a short span; the precise center is the 

center of this span. 

  NOTE:  There may be additional metal material 

deeper in the wall, but only the closest metal 

object’s depth is displayed.

Federal Communications Commission

WARNING: Changes or modi

fi

 cations to this unit not ex-

pressly approved by the party responsible for compliance 

could void the user’s authority to operate the equipment.

This equipment has been tested and found to comply with 

the limits for a Class B digital device, pursuant to Part 15 

of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference in a 

residential installation. This equipment generates, uses 

and can radiate radio frequency energy and, if not installed 

and used in accordance with the instructions, may cause 

harmful interference to radio communications.

However, there is no guarantee that interference will not 

occur in a particular installation. If this equipment does 

cause harmful interference to radio or television reception, 

which can be determined by turning the equipment off and 

on, the user is encouraged to try to correct the interference 

by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and 

receiver.

• Connect the equipment into an outlet on a circuit different 

from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician 

for help.

• Have your Sub-Scanner serviced by a qualifi ed 

repair person using only identical replacement 
parts. 

This will ensure that the safety of the tool is 

maintained.

• Do not disassemble.

 Incorrect reassembly may 

result in the risk of electric shock or 

fi

 re. If it is dam-

aged, take it to a 

MILWAUKEE

 service facility.

• Store in a cool, dry place. 

Do not store where 

temperatures may exceed 140°F (60°C) such as 

in direct sunlight, a vehicle or metal building during 

the summer. 

• Do not remove or deface labels. Maintain labels 

and nameplates. 

These carry important information. 

If unreadable or missing, contact a

 MILWAUKEE

 

service facility for a free replacement.

Specifi cations

Metal Mode depth accuracy: 

±0.5" at 0.5" up to 6.0" depth

Metal Mode center accuracy: 

±0.5" at 0.5" up to 6.0" depth

Stud Mode center accuracy: 

±0.5" at 0.5" up to 1.5" depth

Drop test:

 1 meter

Operating temperature: 

-5°C to 40°C (23°F to 104°F)

Storage temperature: 

 -20°C to 60°C 

(

-4°F to 140°F)  

 

  without battery

Voltage:

 12 DC 

Battery run time: 

Greater than 12 hrs with all functions

METAL

PLACE ON SURFACE TO

CALIBRATE STANDARD SCAN

PRESS ‘CAL’ TO START

OR ‘METAL’ FOR DEEP SCAN

1. Wheels
2. Display
3. Battery  pack

MET

A

L

STUD

MENU

CAL

4

5

6

8

3

4. On/Off  button
5. Stud Scan/Down button
6. Calibrate  button
7. Menu  button
8. Metal Scan/Up button

2

7

1

1

METAL

SCANNING...

STANDARD SCAN

METAL

CALIBRATING

STANDARD SCAN

Содержание M12 SUB-SCANNER 2291-20

Страница 1: ...IENTA DE DETECCIÓN SUB SCANNER DE M12 Cat No No de Cat 2291 20 TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND OPERATOR S MANUAL AFIN DE RÉDUIRE LE RISQUE DE BLESSURES L UTILISATEUR DOIT LIRE ET BIEN COMPRENDRE LE MANUEL DE L UTILISATEUR PARA REDUCIR EL RIESGO DE LESIONES EL USUARIO DEBE LEER Y ENTENDER EL MANUAL DEL OPERADOR ...

Страница 2: ...ings Alternating surfaces such as thick grout lines or extremely heavy plaster on drywall may be detected or show as metal or studs 1 Turn on the Sub Scanner 2 Select Metal mode default 3 Standard depth of scan up to 4 deep scan is defaulted Press the Metal button to switch to Deep depth of scan up to 6 deep scan NOTE Deep mode scans may display more noise due to the higher sensitivity of the scan...

Страница 3: ...nter freight prepaid and insured is required Acopy of the proof of purchase should be included with the return product This warranty does not apply to damage that MILWAUKEE determines to be from repairs made or attempted by anyone other than MILWAUKEE authorized personnel misuse alterations abuse normal wear and tear lack of maintenance or accidents The warranty period for the LITHIUM ION battery ...

Страница 4: ...bouton Calibrate Étalonnage pour choisir l option désirée UNITÉS Permet de choisir l affichage en unités anglaises ou métriques SON Permet d activer ou de désactiver la fonction de sourdine 4 Appuyer de nouveau sur le bouton MENU pour quitter le mode Sélection du mode 1 Mettre le scanneur en marche 2 Le mode Metal Métal constitue le réglage par défaut 3 Pour alterner entre le mode METAL Métal et S...

Страница 5: ... et déplacer le scanneur de 152 mm 6 de l un ou l autre des côtés avant de procéder à l étalonnage 5 Si l indication SCANNING É t a l o n n a g e s affiche déplacez le scanneur à travers la surface Tenir la main libre et les autres ob jets à une distance d au moins 152 mm 6 de l outil pour éviter d obtenir une lecture erronée NOTE Le scanneur doit demeurer à plat contre la surface pendant toute la...

Страница 6: ... une copie de la preuve d achat au centre de réparations en usine MILWAUKEE société d outils électriques le plus près Cette garantie ne couvre pas les dommages que MILWAUKEE détermine être causés par des réparations ou des tentatives de réparation par quiconque autre que le personnel agréé par MILWAUKEE des utilisations incorrectes des altérations des utilisations abusives une usure normale une ca...

Страница 7: ...amienta deslícela sobre el cuerpo de la herramienta Asegúrese de que se asegura bien en su posición Federal Communications Commission ADVERTENCIA Los cambios o modificaciones hechos a esta unidad sin la autorización expresa del responsable del cumplimiento de la norma podrían anular la autoridad del usuario para manejar el equipo Se ha verificado y determinado que este equipo cumple con los límite...

Страница 8: ...de fabricación del producto para determinar el período de garantía en caso de no pre sentarse el comprobante de la compra en el momento de solicitar el servicio de garantía LAACEPTACIÓN DE LOS DERECHOSAREPARACIÓN Y REEMPLAZO EXCLUSIVAMENTE DESCRITOS EN EL PRESENTE DOCUMENTO CONSTITUYE UNA CONDICIÓN DEL CONTRATO POR LA COMPRA DE CADA PRODUCTO MILWAUKEE SI NO ACEPTA ESTA CONDICIÓN NO DEBE COMPRAR EL...

Страница 9: ...ENTRO DE ATENCIÓN A CLIENTES Rafael Buelna No 1 Col Tezozomoc Delegación Azcapotzalco México D F Telefono sin costo 01 800 832 1949 e mail servicio ttigroupna com Adicionalmente tenemos una red nacional de distribuidores autorizados listos para ayudarle con su herramienta y sus accesorios Por favor llame al 01 800 832 1949 para obtener los nombres y direcciones de los más cercanos a usted o con su...

Отзывы: