background image

OM-246 022 Page 3

1-3. Additional Symbols For Installation, Operation, And Maintenance

FIRE OR EXPLOSION hazard.

D

Do not install or place unit on, over, or near

combustible surfaces.

D

Do not install unit near flammables.

D

Do not overload building wiring 

 be sure power supply system is

properly sized, rated, and protected to handle this unit.

FALLING EQUIPMENT can injure.

D

Use lifting eye to lift unit only, NOT running

gear, gas cylinders, or any other accessories.

D

Use equipment of adequate capacity to lift and

support unit.

D

If using lift forks to move unit, be sure forks are long enough to

extend beyond opposite side of unit.

D

Keep equipment (cables and cords) away from moving vehicles

when working from an aerial location.

D

Follow the guidelines in the Applications Manual for the Revised

NIOSH Lifting Equation (Publication No. 94

110) when manu-

ally lifting heavy parts or equipment.

OVERUSE can cause OVERHEATING

D

Allow cooling period; follow rated duty cycle.

D

Reduce current or reduce duty cycle before

starting to weld again.

D

Do not block or filter airflow to unit.

FLYING SPARKS can injure.

D

Wear a face shield to protect eyes and face.

D

Shape tungsten electrode only on grinder with

proper guards in a safe location wearing proper

face, hand, and body protection.

D

Sparks can cause fires — keep flammables away.

STATIC (ESD) can damage PC  boards.

D

Put on grounded wrist strap BEFORE handling

boards or parts.

D

Use proper static-proof bags and boxes to

store, move, or ship PC boards.

MOVING PARTS can injure.

D

Keep away from moving parts.

D

Keep away from pinch points such as drive

rolls.

WELDING WIRE can injure.

D

Do not press gun trigger until instructed to do

so.

D

Do not point gun toward any part of the body,

other people, or any metal when threading

welding wire.

MOVING PARTS can injure.

D

Keep away from moving parts such as fans.

D

Keep all doors, panels, covers, and guards

closed and securely in place.

D

Have only qualified persons remove doors, panels, covers, or

guards for maintenance and troubleshooting as necessary.

D

Reinstall doors, panels, covers, or guards when maintenance is

finished and before reconnecting input power.

READ INSTRUCTIONS.

D

Read and follow all labels and the Owner’s

Manual carefully before installing, operating, or

servicing unit. Read the safety information at

the beginning of the manual and in each

section.

D

Use only genuine replacement parts from the manufacturer.

D

Perform maintenance and service according to the Owner’s

Manuals, industry standards, and national, state, and local

codes.

H.F. RADIATION can cause interference.

D

High-frequency (H.F.) can interfere with radio

navigation, safety services, computers, and

communications equipment.

D

Have only qualified persons familiar with

electronic equipment perform this installation.

D

The user is responsible for having a qualified electrician prompt-

ly correct any interference problem resulting from the installa-

tion.

D

If notified by the FCC about interference, stop using the

equipment at once.

D

Have the installation regularly checked and maintained.

D

Keep high-frequency source doors and panels tightly shut, keep

spark gaps at correct setting, and use grounding and shielding to

minimize the possibility of interference.

ARC WELDING can cause interference.

D

Electromagnetic energy can interfere with

sensitive electronic equipment such as

computers and computer-driven equipment

such as robots.

D

Be sure all equipment in the welding area is

electromagnetically compatible.

D

To reduce possible interference, keep weld cables as short as

possible, close together, and down low, such as on the floor.

D

Locate welding operation 100 meters from any sensitive elec-

tronic equipment.

D

Be sure this welding machine is installed and grounded

according to this manual.

D

If interference still occurs, the user must take extra measures

such as moving the welding machine, using shielded cables,

using line filters, or shielding the work area.

Содержание OM-246 022B

Страница 1: ...OM 246 022B 2010 12 Visit our website at www MillerWelds com Wireless Remote Controls ...

Страница 2: ... Within The EU 8 3 3 Compatibility Chart 9 3 5 Introduction 10 3 6 Battery Installation 10 3 7 Connecting Receiver To Remote 14 Receptacle 11 3 8 Remote Foot Control Operation 11 3 9 Hand Control Operation 12 3 10 Remote Amperage Or Voltage Control For Welding Power Source With Output Always On 13 3 11 Remote Control For Welding Power Source With Output Contactor And Amperage Or Voltage Control 14...

Страница 3: ...or when there is a high risk of unavoid able or accidental contact with the workpiece or ground For these conditions use the following equipment in order presented 1 a semiautomaticDC constant voltage wire welder 2 a DC manual stick welder or 3 an AC welder with reduced open circuit volt age In most situations use of a DC constant voltage wire welder is recommended And do not work alone D Disconne...

Страница 4: ... Standards D Do not weld where the atmosphere may contain flammable dust gas or liquid vapors such as gasoline D Connect work cable to the work as close to the welding area as practical to prevent welding current from traveling long possibly unknown paths and causing electric shock sparks and fire hazards D Do not use welder to thaw frozen pipes D Remove stick electrode from holder or cut off weld...

Страница 5: ... panels covers and guards closed and securely in place D Have only qualified persons remove doors panels covers or guards for maintenance and troubleshooting as necessary D Reinstall doors panels covers or guards when maintenance is finished and before reconnecting input power READ INSTRUCTIONS D Read and follow all labels and the Owner s Manual carefully before installing operating or servicing u...

Страница 6: ... web site www ansi org Standard for Fire Prevention During Welding Cutting and Other Hot Work NFPA Standard 51B from National Fire Protection Association Quincy MA 02269 phone 1 800 344 3555 website www nfpa org OSHA Occupational Safety and Health Standards for General Indus try Title 29 Code of Federal Regulations CFR Part 1910 Subpart Q and Part 1926 Subpart J from U S Government Printing Office...

Страница 7: ...uncture repair disassemble or modify the battery D Charge battery only with supplied charger in an open well ventil ated location out of direct sunlight and according to supplied in structions D Do not overcharge a battery or charge battery longer than spe cified if charger is not equipped with automatic shutoff See the Owner s Manual for specific information on battery charging D Do not charge ba...

Страница 8: ......

Страница 9: ...t into an outlet on a circuit different from that to which the receiver is connected S Consult the dealer or an experienced radio TV technician for help 3 2 Specifications Specification Foot Pedal Transmitter Hand Control Transmitter Receiver Power Supply 3 AA Batteries 3 AA Batteries 10 35 Volts AC or DC Rated Range 90 ft 27 m 300 ft 91 m N A Battery Life Alkaline 250 Hours 250 Hours N A Humidity...

Страница 10: ... EU Do not discard product where ap plicable with general waste Reuse or recycle Waste Electrical and Electronic Equipment WEEE by disposing at a designated collec tion facility Contact your local recycling office or your local distributor for further information ...

Страница 11: ...Maxstar 200 SD DX LX Yes Yes Maxstar 200 STR No No Maxstar 350 700 Yes Yes Miller Du Op Yes Yes Millermatic All No No PipePro 304 Yes 6 Yes 6 PipePro 450 RFC No No Pipeworxt Yes 9 Yes 10 PRO 300 Yes Yes Renegadet 180 No No Shopmatet 300 Yes Yes SRH 444 No No Subarc DC 650 1000 Yes Yes Summit Arct 1000 1250 Yes Yes Syncrowave 200 Yes Yes 2 Syncrowave 250DX 350LX Yes Yes Thunderbolt No No Trailblaze...

Страница 12: ...ntrol transmitter has a unique address The receiver stores the address in permanent memory The receiver can only receive information from a single transmitter A transmitter can only communicate with a single receiver The receiver can learn a new foot pedal or hand control address see sections 3 12 or 3 13 in this manual for programming instructions Programming is only required for devices pur chas...

Страница 13: ...nstant on LED Power on Blinking LED Communicating with transmitter Slow blinking LED Address learn ing mode NOTICE To remove receiver ro tate yellow nut counterclockwise 1 3 2 3 8 Remote Foot Control Operation Unexpected weld output can cause electrical shock Wire less remote control can turn weld output on from distant locations Disconnect receiver from remote 14 receptacle and remove battery fro...

Страница 14: ...er source the remote control contactor button and blue LED output indicator are not valid 4 Increase Button 5 Decrease Button Press and release either button to change selected parameter in 1 percent increments Press and hold either but ton to change selected parameter in 5 percent increments 6 Display Screen Displays selected parameter percent age amperage or voltage The display screen stays illu...

Страница 15: ...ED 6 Display Screen 7 Display Screen Button Output contactor control button does not turn on off welding power source output contactor The output contactor control button is used to activate the display for viewing actual amper age and voltage if the machine has these cap abilities To activate press and hold for 1 second To deactivate press and release Press increase decrease button to illuminate ...

Страница 16: ... Display Screen 7 Display Screen Button Press and hold output contactor control button 1 second to turn on welding power source output contactor Display screen and remote output on indicator blue LED stay on while output contactor is on To turn off weld output contactor press output contactor control button Display screen stays illuminatedfor 10 seconds and then defaults to the percentage mode Pre...

Страница 17: ...chased as a pair Programming is only required for devices that have not been pro grammed paired Once the devices have been paired the address is saved and can only be changed if the programming procedure is conduc ted with a new device Only one con trol can operate a receiver 1 Receiver 2 LED 3 Learn Button Be sure receiver has been correctly connected to the power source Re mote 14 receptacle see...

Страница 18: ...nly required for devices that have not been programmed paired Once the devices have been paired the address is saved and can only be changed if the programmingprocedure is con ducted with a new device Only one control can operate a re ceiver 1 Receiver 2 LED 3 Learn Button Miller Logo Be sure receiver has been cor rectly connected to the power source Remote 14 receptacle see Section 3 7 before pro...

Страница 19: ...er Unplug receptacle connect ing board Reinstall electrical box cover Reinstall right side generator panel 1 Tools Needed 2 3 8 1 2 in SECTION 4 TROUBLESHOOTING Trouble Remedy Remote completely inoperative Green receiver LED not on Make sure power source is on Make sure receiver is connected properly to welding power source see Section 3 7 Green receiver LED is on but no or limited control with re...

Страница 20: ...th respect to pin D B Activates machine output contactor Closure from pin A REMOTE OUTPUT CONTROL C Command supply voltage 0 10 VDC with respect to pin D D Remote control circuit common E Command percentage of pin C supply voltage with respect to pin D A V AMPERAGE VOLTAGE F Current feedback from power source 1 volt DC per 100 amperes H Voltage feedback from power source 1 volt DC per 10 volts out...

Страница 21: ...OM 246 022 Page 19 Notes ...

Страница 22: ...OM 246 022 Page 20 SECTION 6 PARTS LIST 805 481 B 1 3 4 5 6 8 10 11 12 13 15 16 17 18 19 7 9 14 2 ...

Страница 23: ...218006 Label belt installation 1 15 182626 Spring 1 16 183956 Potentiometer w leads Includes 1 17 R1 183463 Pot cp spcl flat loc hole 1t 2 w 1k spcl taper 1 18 C1 2 166197 Capacitor cer disc 1 UF 500 VDC Z5U 2 19 RC1 131197 Conn rect mini 045 3pin 1row rcpt cable panel lkg 1 When ordering a component originally displaying a precautionary label the label should also be ordered To maintain the facto...

Страница 24: ...TM 216 869 Page 22 Dynasty 350 700 Maxstar 350 700 Notes ...

Страница 25: ...ables No Labor 5 6 Months Parts Batteries Bernard Guns No Labor Tregaskiss Guns No Labor 6 90 Days Parts Accessory Kits Canvas Covers Induction Heating Coils and Blankets Cables and Non Electronic Controls M Guns MIG Guns and Subarc SAW Guns Remote Controls and RFCS RJ45 Replacement Parts No labor Roughneck Guns Spoolmate Spoolguns Miller s True Blue Limited Warranty shall not apply to 1 Consumabl...

Страница 26: ...h your personal records Always provide Model Name and Serial Style Number Contact a DISTRIBUTOR or SERVICE AGENCY near you Welding Supplies and Consumables Options and Accessories Personal Safety Equipment Service and Repair Replacement Parts Training Schools Videos Books Technical Manuals Servicing Information and Parts Circuit Diagrams Welding Process Handbooks Contact the Delivering Carrier to ...

Отзывы: