OM-257 675 Page 66
10-4. Front Panel Controls - Continued (See Section 10-3)
8. Arc Control LED
The LED lights to indicate the Arc Control
button is active. Light goes out when button is
inactive.
9. Arc Control Push Button
This push button allows fine tuning inductance
for MIG programs, and Arc Control for
programs other than MIG. In a MIG process
the user can toggle between Slope (SLPE)
and Inductance (INDU). When the push
button is pressed, the upper display (item 15)
shows INDU/SLPE for inductance/slope, or
ARC for Arc Control to indicate which
parameter is selected for change. The
Inductance and Slope range is 0-100. All other
processes use Arc Control with a range of
0-50 (nominal value is 25). Turn the Adjust
knob to change the parameter value. Press
button to deactivate arc control mode (LED
goes out).
10. Wire Feed/Gas/Contactor LEDs
The Wirefeed LED lights when the wire feeder
is energized. For example, when the front
panel Jog or Retract button is pressed, the
Wirefeed LED lights.
The Gas LED lights when the gas valve is
energized.
The Contactor LED lights when the output
contactor is energized, making the weld
output terminals live.
11. Wire Speed And Amps LEDs
The lit LED indicates whether wire speed or
amps are being displayed.
12. Wire Feed Speed/Amps Display Push
Button
13. Lower Display
Press Wire Feed Speed/Amps Display button
to show weld amperage or wire feed speed in
lower display (the applicable LED under the
lower display lights to indicate which is
shown). When welding, actual value is shown.
If amperage was selected for display, the unit
will show actual welding amperage prior to
and while welding unless the the unit is in
Display Command Values mode. Only wire
speed command will be displayed while
welding if the unit is set in Display Command
Values mode, even if the Wire Feed
Speed/Amps Display button is pressed.
.
Displays show actual or command values
as determined by configuration menu
when using the web pages. Command
values are displayed prior to welding and
actual values are displayed while welding
unless the web pages were used to set
the unit in the ”Display Command Values”
mode. In the Display Command Values
mode, command values are displayed
while welding.
.
If the web pages are used to change wire
feed units (IPM, MPM) or display welding
information (command or actual),save the
changes and then turn the power to the unit
off and then on again for the changes to be
carried out by the unit.
14. Volts And Arc Adjust LEDs
The lit LED indicates whether voltage or arc
length is being displayed.
15. Upper Display
The upper display shows different information
depending on the active function of the unit
and the weld process being used. When the
display shows voltage (for a MIG process),
the Volts LED lights. When it shows arc adjust
[for a pulsed and RMD (optional) weld
process], the Arc Adjust LED lights. However,
during any weld process (MIG and pulse), the
unit will display actual arc voltage unless the
web pages were used to set the unit in the
”Display Command Values” mode.
16. Lock LED
The lock LED is illuminated when the
“Global Locks Enable” has been turned on
using the web pages
Table 9-1. Welding Wire And Gas Abbreviations*
Wire Description
Wire Abbreviation
Alloy Type
Gas Type
Gas Abbreviation
Steel
STL
E70, E100, E120
100% CO
2
,
90% Argon/10% CO
2
,
85% Argon/15% CO
2
,
80% Argon/20% CO
2
,
75% Argon/25% CO
2
,
95% Argon/5% CO
2
,
95% Argon /5% O
2
,
98% Argon/2% O
2
CO2
C10
C15
C20
C25
C5
OX5
OX2
Stainless Steel
SS
308, 309, 312, 316
98% Argon, 2% O
2
(81Ar/18HE/1CO
2
Accu-pulse),
90HE/7-1/2Ar/2-1/2CO
2
MIG/Accu-pulse),
98% Argon/2% CO
2
OX2
Tri Gas
HE90
C2
Cored Tubular Wire
MCOR
71, 76, 86R, 409, 439,
MATRIX
90% Argon/10% CO
2,
98% Argon/2% O
2,
95% Argon/5% CO
2
,
95% Argon /5% O
2
,
100% CO
2
C10
OX2
C5
OX5
CO2
Aluminum
ALUM
4XXX, 5XXX
100% Argon
ARGN
Flux Cored Tubular Wire
FCOR
E70T-0
E70T-1
100% CO
2
75% Argon/25% CO
2
CO2
C25
Silicon Bronze Wire
SIBR
CUSI
100% Argon
ARGN
* Not all wire types may be available with your unit.
Содержание Auto-Axcess E Digital
Страница 6: ......
Страница 16: ...OM 257 675 Page 10...
Страница 18: ...OM 257 675 Page 12 Notes...
Страница 22: ...OM 257 675 Page 16 Notes...
Страница 26: ...OM 257 675 Page 20 Notes...
Страница 30: ...OM 257 675 Page 24 Notes...
Страница 37: ...General OM 257 675 Page 31 Notes...
Страница 98: ...Safety OM 257 675 Page 92 Notes...
Страница 115: ...Trouble OM 257 675 Page 109 Notes...
Страница 120: ...OM 257 675 Page 114 Figure 15 2 Circuit Diagram For Auto Axcess E 300 Digital Welding Power Source Part 2 Of 2...
Страница 121: ...Circuits OM 257 675 Page 115 257 679 A Part 2 Of 2...
Страница 122: ...OM 257 675 Page 116 Figure 15 3 Circuit Diagram For Auto Axcess E 450 Digital Welding Power Source Part 1 Of 2...
Страница 123: ...Circuits OM 257 675 Page 117 257 678 A Part 1 Of 2...
Страница 124: ...OM 257 675 Page 118 Figure 15 4 Circuit Diagram For Auto Axcess E 450 Digital Welding Power Source Part 2 Of 2...
Страница 125: ...Circuits OM 257 675 Page 119 257 678 A Part 2 Of 2...
Страница 126: ...OM 257 675 Page 120 Figure 15 5 Circuit Diagram For Auto Axcess E 675 Digital Welding Power Source Part 1 Of 2...
Страница 127: ...Circuits OM 257 675 Page 121 257 676 A Part 1 Of 2...
Страница 128: ...OM 257 675 Page 122 Figure 15 6 Circuit Diagram For Auto Axcess E 675 Digital Welding Power Source Part 2 Of 2...
Страница 129: ...Circuits OM 257 675 Page 123 257 676 A Part 2 Of 2...
Страница 130: ...OM 257 675 Page 124 Figure 15 7 Circuit Diagram For Axcess E Digital Module...
Страница 131: ...Circuits OM 257 675 Page 125 257 680 A...
Страница 132: ...OM 257 675 Page 126 Figure 15 8 Circuit Diagram For Motor And Digital I O Interface...
Страница 133: ...Circuits OM 257 675 Page 127 258 246 A...
Страница 143: ...E450 Parts OM 257 675 Page 137 Notes...