OM-228 874 Page 36
8-2.
Diagnostics (Continued)
WELD WAIT
The weld wait erro
r indicates unit was not
ready for a weld sequence. Press Jog/
Purge button to clear error.
MOTR COM
The motor communication erro
r indi-
cates motor board lost data communica-
tions. Press Jog/Purge button to clear error.
If condition persists, contact nearest factory
authorized Service Agent.
PLS WAIT
The uim communication erro
r indicates
user interface board lost data
communications. Press Jog/Purge button
to clear error. If condition persists, contact
nearest factory authorized Service Agent.
LOW WFS
The low wire feed speed erro
r indicates
actual wire feed speed is lower than wire
feed speed command. Check for
obstructions in the wire feed system or a
faulty wire drive system. Press Jog/Purge
button to clear error.
REL TRIG
The release trigger erro
r indicates the
user held the gun trigger after an E stop was
reset causing the contactor to remain on.
Press Jog/Purge button to clear error.
ROBT MEM
The robot memory error
indicates robot
lost memory data. Press Jog/Purge button
to clear error.
E STOP
The emergency stop error
occurs if the
user presses an emergency stop button.
Reset the emergency stop button and press
Jog/Purge button to clear error. Only applies
to units equipped with E stop option.
DEMO DONE
The DEMO done message
indicates the
RMD and Accuspeed demos are comple-
ted. Pressing Jog/Purge button will change
the screen to CYCL PWR on the display.
Turn unit power off and back on again. RMD
and Accuspeed share the same demo timer.
If the time expires for one demo process,
both demo processes are deactivated.
OVER AVG
The over average error
indicates that
current is outside the average range for the
set program parameters. Check and correct
program parameters. Press Jog/Purge
button to clear error.
TRIG STUK
The trigger stuck erro
r indicates the user
held the gun trigger during power up.
Release trigger and turn power off and back
on.
UNIT COMM
The unit communication error
indicates
the data bus on the PCM board is not
functioning properly. Press Jog/Purge
button to clear error.
OVER CRNT
The over current erro
r indicates welding
power source primary current of the inverter
is too high.
Turn welding power source off
and disconnect unit for servicing.
Attempting to reset the display to
continue welding may further damage
internal components.
A complete
prepower check of the unit is needed
including resistance measurements of R1
and R8 resistors on welding power source
Interconnect board. Resistors should
measure 30K ohms. Visually inspect
electrolytic capacitors C1 and C2 for any
possible damage. In the event of an over
voltage condition, R1 and R8 could open
potentially causing an imbalance in the
power circuit. This condition would create
excessive current in the inverter primary
transformer and result in the OVER CRNT
error.
ERR UNKN
The unknown erro
r indicates an error was
sent from the PCM board to the UIM, but
error condition is unknown. Make sure
welding power source is isolated from the
welding fixture. Press Jog/Purge button to
clear error.
WELD
WAIT
MOTR
COM
PLS
WAIT
Indicates a weld
cycle wait error.
Indicates a motor
communication error.
Indicates a UIM
communication error.
LOW
Indicates a low WFS
command error.
WFS
ROBT
MEM
E
STOP
DEMO
DONE
OVER
AVG
Indicates a CRC
robot memory error.
Indicates an
emergency stop error.
Indicates RMD/Ac-
cuspeed demo is
expired.
Indicates an over
average current error.
UNIT
COMM
Indicates a CRC
PCM bus error.
OVER
CRNT
Indicates an
overcurrent error.
REL
TRIG
ERR
UNKN
Indicates a contactor
on error.
Indicates an
unknown error.
TRIG
STUK
Indicates a trigger
closed error.
Содержание Auto-Axcess 300 DI
Страница 14: ...OM 228 874 Page 10...
Страница 25: ...OM 228 874 Page 21 Notes...
Страница 48: ...OM 228 874 Page 44 Figure 9 2 Circuit Diagram For Welding Power Source Part 2 Of 2...
Страница 49: ...OM 228 874 Page 45 228 875 F Part 2 Of 2...
Страница 50: ...OM 228 874 Page 46 Ref 219 267 B Figure 9 3 Circuit Diagram For Peripheral Motor Interface...
Страница 51: ...OM 228 874 Page 47 Notes...