OM-228 874 Page 35
8-2. Diagnostics
ERR TACH
Tach error
for Tach A occurs 2 seconds
after the loss of tachometer feedback. The
motor speed is regulated through the
monitoring of voltage and current. Press
Jog/Purge button to clear error.
Tach error
for Tach B occurs 2 seconds
after the loss of tachometer feedback. The
motor speed is regulated through the
monitoring of voltage and current. Press
Jog/Purge button to clear error.
ERR MOTR
The motor error
indicates that the motor
has been drawing too much current for too
long. To remedy this, reduce the wire feed
speed or the wire feeder torque load/duty
cycle. Press Jog/Purge button to clear error.
ERR WFS
The wire feed speed error
indicates actual
wire feed speed does not match wire feed
speed command. Press Jog/Purge button
to clear error.
ERR STRT
The start erro
r, when enabled, occurs if the
trigger is held longer than three seconds
without an arc start. The error may be
cleared by releasing the trigger, and
pressing the Jog/Purge button.
ERR STOP
The stop error
occurs as result of
obstructions in the wire feed system or a
faulty wire drive system. Check wire feed
and wire drive systems. Press Jog/Purge
button to clear error.
ERR FLOW
The flow error
indicates no gas flow to the
gun. The error may be reset by
reestablishing gas flow to the gun, and then
pressing the Jog/Purge button.
ERR COOL
The cool error
indicates no coolant flow in
water flow switch option. The error may be
reset by reestablishing coolant flow to the
gun, and then pressing the Jog/Purge
button.
ERR GND
The ground current error
occurs if weld
current is detected in the earth ground
connection. May be caused by a conductor
making contact with unit chassis. Check
and repair feeder weld connections. Turn
power off and back on to clear error.
ERR STUK
The stuck error
occurs if the welding wire
sticks to the workpiece at the end of a weld.
May be caused by poor weld conditions.
The error may be cleared by cutting wire
from workpiece, and pressing the Jog/
Purge button.
ERR TEMP
The temperature error
indicates welding
power source has overheated and
shutdown. The error may be cleared by
allowing unit to cool down, and pressing the
Jog/Purge button. If problem persists,
check fan motors and thermistors for proper
operation. If unit is not overheated, check in-
put line voltage. If input line voltage is okay,
contact nearest factory authorized Service
Agent.
ERR LINE
The line error
indicates input power is
outside of unit operating range. Check and
correct input power. Press Jog/Purge
button to clear error.
ERR ARC
The arc error
indicates an arc outage
occurred possibly from a wire feeder error
or power source error. Check wire feeder
and power source. Press Jog/Purge button
to clear error.
The following error messages are shown on the
upper and lower displays to indicate specific errors.
Explanations are in the text below:
ERR
TACH
ERR
MOTR
ERR
WFS
ERR
STRT
ERR
STOP
Indicates a
tachometer error.
Indicates a motor
error.
Indicates a wire
feed speed error.
Indicates an arc
start error.
Indicates an arc
stop error.
ERR
FLOW
ERR
COOL
ERR
GND
ERR
STUK
Indicates a gas
flow error.
Indicates a coolant
flow error.
Indicates a ground
current error.
Indicates a wire
stuck error.
ERR
TEMP
ERR
LINE
ERR
ARC
Indicates a
temperature error.
Indicates a line
error.
Indicates an arc
error.
Содержание Auto-Axcess 300 DI
Страница 14: ...OM 228 874 Page 10...
Страница 25: ...OM 228 874 Page 21 Notes...
Страница 48: ...OM 228 874 Page 44 Figure 9 2 Circuit Diagram For Welding Power Source Part 2 Of 2...
Страница 49: ...OM 228 874 Page 45 228 875 F Part 2 Of 2...
Страница 50: ...OM 228 874 Page 46 Ref 219 267 B Figure 9 3 Circuit Diagram For Peripheral Motor Interface...
Страница 51: ...OM 228 874 Page 47 Notes...