OM-228 874 Page 34
SECTION 8
−
TROUBLESHOOTING
8-1. Set Value Mode
The Set Value mode is a troubleshooting tool
that allows certain robot command values to
be manually over-ridden.
1
Setup Push Button
2
Arc Control Push Button
3
Adjust Knob
4
Wire Feed Speed/Amps Display Push
Button
Enter the Set Value mode by pressing the
Setup and Arc Control push buttons at the
same time. When in the Set Value mode the
display windows briefly shows SET VALU and
the blinking LEDs under the display windows
indicate whether Volts, Arc Adjust, or Wire
Speed can be changed turning the Adjust
knob.
Depending on the defined weld process,
either volts (MIG) or arc adjust [pulse,
Accu-pulse, or RMD (optional)] can be
changed in the top display. Wire speed can be
changed in the bottom display. Press the Wire
Feed Speed/Amps push button to toggle
between selecting information in the top
display or bottom display. The LED under the
active display will blink to indicate the value
that can be changed.
Rotate the Adjust knob to change values.
Exit the Set Value mode by pressing the Setup
and Arc Control push buttons at the same time
or turning power source off and then back on
again.
Set Value mode overrides robot wire feed
speed, voltage, and trim commands. To weld
in this mode, the robot only needs to provide
a contactor signal, and voltage and wire feed
speed will be ignored.
Program
Process
Wire Type
Gas Type
Adjust
Volts
Arc Adjust
Wire Speed
Amps
Setup
Arc Control
Wirefeed
Gas
Contactor
1
2
3
4
Содержание Auto-Axcess 300 DI
Страница 14: ...OM 228 874 Page 10...
Страница 25: ...OM 228 874 Page 21 Notes...
Страница 48: ...OM 228 874 Page 44 Figure 9 2 Circuit Diagram For Welding Power Source Part 2 Of 2...
Страница 49: ...OM 228 874 Page 45 228 875 F Part 2 Of 2...
Страница 50: ...OM 228 874 Page 46 Ref 219 267 B Figure 9 3 Circuit Diagram For Peripheral Motor Interface...
Страница 51: ...OM 228 874 Page 47 Notes...