background image

OM-228 874 Page 11

SECTION 3 

 DEFINITIONS

3-1. Manufacturer’s Warning Label Definitions

Warning! Watch Out! There are possible hazards as shown by the symbols.

Safe1 2012

05

Wear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves.

Safe2 2012

05

Protect yourself from electric shock by insulating yourself from work and ground.

Safe3 2012

05

Disconnect input plug or power before working on machine.

Safe5 2012

05

Keep your head out of the fumes.

Safe6 2012

05

Use forced ventilation or local exhaust to remove the fumes.

Safe8 2012

05

Use ventilating fan to remove fumes.

Safe10 2012

05

Keep flammables away from welding. Do not weld near flammables.

Safe12 2012

05

Welding sparks can cause fires. Have a fire extinguisher nearby, and have a watchperson ready to use it.

Safe14 2012

05

Do not weld on drums or any closed containers.

Safe16 2012

05

Содержание Auto-Axcess 300 DI

Страница 1: ...Processes Description MIG GMAW Welding Pulsed MIG GMAW P Flux Cored FCAW Welding Automatic Welding Automatic Welding Interface And Arc Welding Power Source File Advanced Manufacturing Systems Visit o...

Страница 2: ...ntinue the tradition They re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929 This Owner s Manual is designed to help you get...

Страница 3: ...LATION 14 4 1 Specifications 14 4 2 Dimensions And Weight 14 4 3 Duty Cycle And Overheating 15 4 4 Volt Ampere Curves 15 4 5 Serial Number And Rating Label Location 15 4 6 Selecting A Location 16 4 7...

Страница 4: ...Input Capacitor Voltage 37 8 4 Process Control Module PC4 Diagnostic LEDs 38 8 5 Diagnostic LEDs On Process Control Module PC4 38 8 6 Wire Feed Module PC6 Diagnostic LEDs And Dip Switch Settings 39 8...

Страница 5: ...ds when in cramped positions such as sitting kneeling or lying or when there is a high risk of unavoid able or accidental contact with the workpiece or ground For these conditions use the following eq...

Страница 6: ...ums or pipes unless they are properly prepared according to AWS F4 1 and AWS A6 0 see Safety Standards D Do not weld where the atmosphere may contain flammable dust gas or liquid vapors such as gasoli...

Страница 7: ...NG PARTS can injure D Keep away from moving parts such as fans D Keep all doors panels covers and guards closed and securely in place D Have only qualified persons remove doors panels covers or guards...

Страница 8: ...ntion During Welding Cutting and Other Hot Work NFPA Standard 51B from National Fire Protection Association Quincy MA 02269 phone 1 800 344 3555 website www nfpa org OSHA Occupational Safety and Healt...

Страница 9: ...utilisation d une source lectrique courant lectrique s av re n cessaire se servir de la fonction de t l commande si l appareil en est quip D D autres consignes de s curit sont n cessaires dans les con...

Страница 10: ...ne et des bottes de protection LE SOUDAGE peut provoquer un incendie ou une explosion Le soudage effectu sur des conteneurs ferm s tels que des r servoirs tambours ou des conduites peut provoquer leur...

Страница 11: ...eur D Utiliser les quipements corrects les bonnes proc dures et suffi samment de personnes pour soulever et d placer les bouteilles D Lire et suivre les instructions sur les bouteilles de gaz comprim...

Страница 12: ...der seulement des personnes qualifi es familiaris es avec des quipements lectroniques de faire fonctionner l installa tion D L utilisateur est tenu de faire corriger rapidement par un lectricien quali...

Страница 13: ...t Q and Part 1926 Subpart J from U S Government Printing Office Super intendentof Documents P O Box 371954 Pittsburgh PA 15250 7954 phone 1 866 512 1800 there are 10 OSHA Regional Offices phone for Re...

Страница 14: ...OM 228 874 Page 10...

Страница 15: ...self from work and ground Safe3 2012 05 Disconnect input plug or power before working on machine Safe5 2012 05 Keep your head out of the fumes Safe6 2012 05 Use forced ventilation or local exhaust to...

Страница 16: ...a designated collection facility Contact your local recycling office or your local distributor for further information Safe37 2012 05 Wear hat and safety glasses Use ear protection and button shirt c...

Страница 17: ...Earth Ground Increase Line Connection Gas Metal Arc Welding GMAW Three Phase Static Frequency Con verter Transformer Rectifier U0 Rated No Load Voltage Average U1 Primary Voltage U2 Conventional Load...

Страница 18: ...A 8 6 0 1A 5 3 0 2 4 9 0 04 Three Phase 225 A 25 3 V DC 100 Duty Cycle 19 9 0 1A 17 8 0 1A 10 9 0 1A 10 3 0 1A 9 0 0 1A 7 3 0 1A 7 1 0 2 6 8 0 04 While idling Input amperage fluctuates while idling an...

Страница 19: ...TION SINGLE PHASE OPERATION DUTY CYCLE WELDING AMPERES 10 15 20 25 30 40 50 60 70 80 90 100 100 150 200 225 250 300 400 500 4 4 Volt Ampere Curves va_curve1 4 95 Volt amperecurves show minimum and max...

Страница 20: ...tile liquids are present see NEC Article 511 or CEC Section 20 Ref 803 675 A Ref 801 915 A The proper interface kit must be installed in the welding power source interface unit to allow it to be conne...

Страница 21: ...rminals 1 2 Ref 803 675 A 803 778 A Turn off power before connecting to weld output terminals Failure to properly connect weld cables may cause excessive heat and start a fire or damage your machine D...

Страница 22: ...5 2 ea 3 0 2x95 2 ea 4 0 2x120 400 1 0 60 2 0 70 3 0 95 4 0 120 2 ea 2 0 2x70 2 ea 3 0 2x95 2 ea 4 0 2x120 2 ea 4 0 2x120 500 2 0 70 3 0 95 4 0 120 2 ea 2 0 2x70 2 ea 3 0 2x95 2 ea 4 0 2x120 3 ea 3 0...

Страница 23: ...574 A Socket Socket Information A Not used B Motor negative C Tach A 0 volts low and 3 5 volts high D Motor positive E Tach common F Gas valve 40 volts DC when valve is on with respect to socket K G E...

Страница 24: ...Code NEC including article 630 1 If a circuit breaker is used in place of a fuse choose a circuit breaker with time current curves comparable to the recommended fuse 2 Time Delay fuses are UL class R...

Страница 25: ...OM 228 874 Page 21 Notes...

Страница 26: ...ble through tubing inside unit 2 218005 C ELECTRIC SHOCK can kill SIGNIFICANT DC VOLTAGE exists after removal of input power S Always wait 5 minutes after power is turned off before working on unit S...

Страница 27: ...mperage capacity and correct hole size Welding Power Source Input Power Connections 2 Strain Relief Install strain relief of proper size for unit and input conductors Route conductors cord through str...

Страница 28: ...ut7 2012 05 Ref 803 766 C 803 676 A Ref 218 005 A Tools Needed 5 16 in Route ground conductor through current transducer to ground terminal Route input power cable through tubing inside unit 7 2 1 6 4...

Страница 29: ...ing conductor through current transducer and connect to welding power source grounding terminal first Then connect input conductors L1 and L2 to welding power source line terminals Reinstall side pane...

Страница 30: ...he welding puddle more fluid MIG CV weld process with individual settings of voltage and wire speed Postflow Setting a time value for gas flow after arc end only available on Auto Axcess models in the...

Страница 31: ...eed In MIG mode wire feed setting is independent of voltage setting In pulse Accu pulse and RMD optional adjusting wire feed speed also increases power level on wire electrode one knob control Wire Ty...

Страница 32: ...When this LED is lit turn the Adjust knob to select the desired wire type wire alloy and size Wire type and size choices vary according to the selected weld process Choices may include steel displaye...

Страница 33: ...d or actual save the changes and then turn the power to the unit off and then on again for the changes to be carried out by the unit 14 Volts And Arc Adjust LEDs The lit LED indicates whether voltage...

Страница 34: ...3 Accu pulse 035 Mild Steel 90 Argon 10 O2 Program 4 Pulse 045 Mild Steel 90 Argon 10 CO2 Program 5 MIG 045 Mild Steel 75 Argon 25 CO2 Program 6 Accu pulse 045 Mild Steel 90 Argon 10 O2 Program 7 Pul...

Страница 35: ...ce To be done by Factory Authorized Service Agent Reference Every 3 Months l Unreadable Labels Weld Terminals l Damaged Gas Hose nl Weld Cables nl Cords nl Gun Cables Every 6 Months OR Drive Rolls Ins...

Страница 36: ...ve unit use the one hand method Do not put both hands inside unit Keep one hand free D Disconnect input power conductors from deenergized supply line BEFORE moving a welding power source SIGNIFICANT D...

Страница 37: ...abels and the Technical Manual carefully be fore installing operating or servicing unit Read the safety in formationat the beginning of the manual and in each section 7 3 California Proposition 65 War...

Страница 38: ...r arc adjust pulse Accu pulse or RMD optional can be changed in the top display Wire speed can be changed in the bottom display Press the Wire Feed Speed Amps push button to toggle between selecting i...

Страница 39: ...error occurs if weld current is detected in the earth ground connection May be caused by a conductor making contact with unit chassis Check and repair feeder weld connections Turn power off and back...

Страница 40: ...ters Check and correct program parameters Press Jog Purge button to clear error TRIG STUK The trigger stuck error indicates the user held the gun trigger during power up Release trigger and turn power...

Страница 41: ...n until voltage drops to near 0 zero volts Measure input capacitor voltage on inverter assembly before proceeding If the capacitor voltage does not drop to near zero after several minutes use a bleede...

Страница 42: ...Diagnostic LEDs 1 LED2 LED1 LED4 LED3 8 5 Diagnostic LEDs On Process Control Module PC4 LED Status Diagnosis 1 On Indicates 25 volts DC is present on process control module PC4 Off Indicates 25 volts...

Страница 43: ...d For proper operation do not change dip settings from those shown 8 6 Wire Feed Module PC6 Diagnostic LEDs And Dip Switch Settings 217 333 B 804 575 A 2 1 LED1 LED2 LED3 LED4 8 7 Diagnostic LEDs On W...

Страница 44: ...p Switch S2 Dip switches are used to identify each circuit board on the internal network Dip switch settings are different for each circuit board For proper operation do not change dip settings from t...

Страница 45: ...the network Red The circuit board has encountered a communication link failure with the network Check DeviceNet cable connections Verify dip switch positions according to Sections 1 2 and 1 3 Replace...

Страница 46: ...ed Check supplementary protector CB2 and reset if necessary Check motor control cable connections Wire feeds erratically Readjust hub tension Readjust drive roll pressure Clean or replace dirty or wor...

Страница 47: ...OM 228 874 Page 43 SECTION 9 ELECTRICAL DIAGRAMS 228 875 F Part 1 Of 2 Figure 9 1 Circuit Diagram For Welding Power Source Part 1 Of 2...

Страница 48: ...OM 228 874 Page 44 Figure 9 2 Circuit Diagram For Welding Power Source Part 2 Of 2...

Страница 49: ...OM 228 874 Page 45 228 875 F Part 2 Of 2...

Страница 50: ...OM 228 874 Page 46 Ref 219 267 B Figure 9 3 Circuit Diagram For Peripheral Motor Interface...

Страница 51: ...OM 228 874 Page 47 Notes...

Страница 52: ...OM 228 874 Page 48 SECTION 10 PARTS LIST Hardware is common and not available unless listed 804 576 D 1 2 3 7 8 9 10 11 12 13 14 Fig 10 5 4 Fig 10 3 5 Fig 10 2 6 Fig 10 4 7 Figure 10 1 Main Assembly...

Страница 53: ...lator 2 8 210482 Base 1 9 213386 Assembly Filter Primary 1 10 HD2 182918 Transducer Current 400A Module Supply V 15V 1 11 198951 Block Terminal 3 Pole 1 12 148025 Lug Univ W SCR 600V 2 0 6 Wire 266 St...

Страница 54: ...1 11 Z1 220496 Output Inductor Assy 1 12 170647 Bushing Snap in Nyl 1 312 Id X 1 500 Mtg Hole 2 13 179276 Bushing Snap in Nyl 1 000 Id X 1 375 Mtg Hole Cent 4 14 196355 Insulator Screw 6 15 010546 Bu...

Страница 55: ...196840 Insulator Resistors Interface Board 1 30 109056 Core Ferrite E 2 164 Lg X 1 094 High X 826 Wide 1 31 196514 Gasket Inductor Mounting 2 32 196512 Bracket Inductor Mounting 2 33 196330 Heat Sink...

Страница 56: ...Panel Hole 312 Sq 500 High 24 6 PC4 221277 Process Control Module 1 7 170647 Bushing Snap in Nyl 1 312 Id X 1 500 Mtg Hole 1 8 210491 Panel Mtg Components Top 1 9 223439 Insulator circuit card Aux Po...

Страница 57: ...9 CB2 093995 Supplementary Protector Man Reset 1P 15A 250VAC Frict 1 10 PC11 239631 Circuit Card Assy Motor Filter HF 1 11 216596 Strap Grounding 4 50 in long 1 12 225955 Plate Mounting E Stop 1 13 RC...

Страница 58: ...Mode Choke 1 9 216965 Cover Connector D sub 9 skt Female w Chain 1 10 216966 Cover Connector D sub 9 pin Male w Chain 1 11 213102 Choke Common Mode w Leads 2 12 210866 Terminal pwr output black 1 13...

Страница 59: ...lies Water Coolant Systems Non Integrated Weldcraft Branded TIG Torches No Labor Wireless Remote Foot Hand Controls and Receivers Work Stations Weld Tables No Labor 5 6 Months Parts Batteries Bernard...

Страница 60: ...your personal records Always provide Model Name and Serial Style Number Contact a DISTRIBUTOR or SERVICE AGENCY near you Welding Supplies and Consumables Options and Accessories Personal Safety Equip...