OM-231185 Page 49
9-11. Diagnostic LEDs On Automation Interface Module PC9 (Continued)
LED
Status
Diagnosis
24
On
Input signal On from relay K4 to indicated wire stuck in weld joint.
Off
Input signal Off from relay K4 to indicate wire is not stuck in weld joint.
25
On
Ind5 volts DC is present on automation interface module PC9.
Off
Ind5 volts DC is not present on automation interface module PC9.
26
On
Input signal on from relay K5 for flow (shielding gas or coolant) present.
Off
Input signal off from relay K5 for flow (shielding gas or coolant) not present.
27
On
Indicates
−
15 volts DC is present on automation interface module PC9.
Off
Indicates
−
15 volts DC is not present on automation interface module PC9.
28
On
Ind15 volts DC is present on automation interface module PC9.
Off
Ind15 volts DC is not present on automation interface module PC9.
29
On
Input signal on from relay K6 for arc detected.
Off
Input signal off from relay K6 for no arc detected.
30, 31
On
See Network Status Table in Section 9-12.
Off
See Network Status Table in Section 9-12.
32
On
Input signal on for aux. relay energized.
Off
Input signal off for aux. relay energized.
33
On
Input signal on touch sensor touch detected.
Off
Input signal off touch sensor touch not detected.
9-12. Network And Module Status LEDs
A.
Network Status LEDs
The following are network status LEDs:
LED1 on the UIM circuit board
LED4 on the WFM and PCM circuit boards
LED30 on the AIM circuit board.
Status
Diagnosis
Off
The circuit board is not on-line with the network or there is no power applied to the circuit board.
Green
The circuit board is operating normally and the on-line connection is made with the network.
Flashing Green
The circuit board is waiting for an on-line connection to be made with the network.
Red
The circuit board has encountered a communication link failure with the network. Check DeviceNet cable connections. Verify
dip switch positions according to Sections 1-2 and 1-3. Replace circuit board if necessary.
B.
Module Status LEDs
The following are module status LEDs:
LED2 on the UIM circuit board
LED3 on the WFM and PCM circuit boards
LED31 on the AIM circuit board.
Status
Diagnosis
Off
There is no power applied to the circuit board or the board software is not executing its functions.
Green
The circuit board is operating normally.
Flashing Red
The circuit board has encountered a recoverable fault. Wait or cycle power to clear fault.
Red
The circuit board has encountered an unrecoverable fault.
Содержание Auto-Axcess 300 CE
Страница 27: ...OM 231185 Page 21 Notes...
Страница 58: ...OM 231185 Page 52 Figure 10 2 Circuit Diagram For Welding Power Source Part 2 Of 2...
Страница 59: ...OM 231185 Page 53 263 490 B Part 2 Of 2 RC1 PLG...
Страница 60: ...OM 231185 Page 54 Figure 10 3 Circuit Diagram For 72 Pin Robot Interface...
Страница 61: ...OM 231185 Page 55 219 266 D...
Страница 62: ...OM 231185 Page 56 Figure 10 4 Circuit Diagram For Peripheral Motor Interface...
Страница 63: ...OM 231185 Page 57 219 267 B...
Страница 72: ...Notes...
Страница 73: ...Notes...
Страница 74: ...Notes...