OM-231185 Page 48
9-11. Diagnostic LEDs On Automation Interface Module PC9
LED
Status
Diagnosis
1
On
Input signal On from robot for jog advance.
Off
Input signal Off from robot for no jog advance.
2
On
Input signal On from robot to energize contactor.
Off
Input signal Off from robot to not energize contactor.
3
On
Input signal On remote program A selected.
Off
Input signal Off remote program A not selected.
4
On
Input signal On remote program C selected.
Off
Input signal Off remote program C not selected.
5
On
Input signal On from E-stop board PC12 for no emergency stop.
Off
Input signal Off from E-stop board PC12 acknowledges E-stop is On from robot.
6
On
Spare 1 not assigned.
Off
Spare 1 not assigned.
7
On
Input signal On Autoset-C selected.
Off
Input signal Off Autoset-C not selected.
8
On
Input signal On Autoset-B selected.
Off
Input signal Off Autoset-B not selected.
9
On
Input signal On Remote Jog on from peripheral plug.
Off
Input signal Off Remote Jog off from peripheral plug.
10
On
Input signal On Remote Purge on from peripheral plug.
Off
Input signal Off Remote Purge off from peripheral plug.
11
On
Input signal On from robot for jog retract.
Off
Input signal Off from robot for no jog retract.
12
On
Input signal On from robot for purge.
Off
Input signal Off from robot for no purge.
13
On
Input signal On remote program B selected.
Off
Input signal Off remote program B not selected.
14
On
Input signal On Touch Sensor on from robot or peripheral plug.
Off
Input signal Off Touch Sensor off from robot or peripheral plug.
15
On
Spare 0 not assigned.
Off
Spare 0 not assigned.
16
On
Spare 2 not assigned.
Off
Spare 2 not assigned.
17
On
Input signal On Autoset-A selected.
Off
Input signal Off Autoset-A not selected.
18
On
Input signal On Autoset-D selected.
Off
Input signal Off Autoset-D not selected.
19
On
Input signal On Remote Retract on from peripheral plug.
Off
Input signal Off Remote Retract off from peripheral plug.
20
On
Input signal On Remote Water Flow on from peripheral plug.
Off
Input signal Off Remote Water Flow off from peripheral plug.
21
On
Input signal On from robot for no emergency stop.
Off
Input signal Off from robot for emergency stop.
23
On
Input signal On from relay K3 for welding power source ready and no detected errors present.
Off
Input signal Off from relay K3 for welding power source not ready, detected errors are present, or unit is
in operating mode preventing the weld ready signal from being enabled.
Содержание Auto-Axcess 300 CE
Страница 27: ...OM 231185 Page 21 Notes...
Страница 58: ...OM 231185 Page 52 Figure 10 2 Circuit Diagram For Welding Power Source Part 2 Of 2...
Страница 59: ...OM 231185 Page 53 263 490 B Part 2 Of 2 RC1 PLG...
Страница 60: ...OM 231185 Page 54 Figure 10 3 Circuit Diagram For 72 Pin Robot Interface...
Страница 61: ...OM 231185 Page 55 219 266 D...
Страница 62: ...OM 231185 Page 56 Figure 10 4 Circuit Diagram For Peripheral Motor Interface...
Страница 63: ...OM 231185 Page 57 219 267 B...
Страница 72: ...Notes...
Страница 73: ...Notes...
Страница 74: ...Notes...