OM-231185 Page 43
9-3. Removing Cover and Measuring Input Capacitor Voltage
!
Turn Off welding power
source, and disconnect in-
put power.
!
Significant DC voltage can
remain on capacitors after
unit is Off. Always check the
voltage as shown to be sure
the input capacitors have
discharged before working
on unit.
Remove cover
1
Power Interconnect Board
PC2
2
Voltmeter
Measure the DC voltage across the
+ bus terminal and
−
bus terminal on
PC2 as shown until voltage drops to
near 0 (zero) volts. Measure input
capacitor voltage on inverter
assembly before proceeding.
.
If the capacitor voltage does
not drop to near zero after
several minutes, use a bleeder
resistor of between 25 and
1000 ohms, at least 5 watts,
#16 AWG 1000 volts DC
insulating rating wire to
discharge the capacitor(s).
3
Typical Bleeder Resistor
An example of a typical bleeder
resistor is shown on this page.
Proceed with job inside unit.
Reinstall cover when finished.
Tools Needed:
8mm (5/16 in.)
802 985 / Ref. 803 679-C
1
2
+ lead to left bus terminal,
−
lead to right bus terminal
3
Typical Bleeder Resistor
#16 AWG 1000 volts DC
insulation rating, approx
76 mm (3 in.) leads
25 to 1000 ohm, 5
watt resistor
Содержание Auto-Axcess 300 CE
Страница 27: ...OM 231185 Page 21 Notes...
Страница 58: ...OM 231185 Page 52 Figure 10 2 Circuit Diagram For Welding Power Source Part 2 Of 2...
Страница 59: ...OM 231185 Page 53 263 490 B Part 2 Of 2 RC1 PLG...
Страница 60: ...OM 231185 Page 54 Figure 10 3 Circuit Diagram For 72 Pin Robot Interface...
Страница 61: ...OM 231185 Page 55 219 266 D...
Страница 62: ...OM 231185 Page 56 Figure 10 4 Circuit Diagram For Peripheral Motor Interface...
Страница 63: ...OM 231185 Page 57 219 267 B...
Страница 72: ...Notes...
Страница 73: ...Notes...
Страница 74: ...Notes...