OM-231185 Page 44
1
Process Control Module PC4
Diagnostic LEDs are visible inside unit,
located on PC4 mounted on the top tray.
Refer to Section 9-5 for information on
diagnostic LEDs.
Reinstall cover after checking diagnostic
LEDs.
216 956-A / Ref. 803 679-C
9-4. Process Control Module PC4 Diagnostic LEDs
1
LED2
LED1
LED4
LED3
9-5. Diagnostic LEDs On Process Control Module PC4
LED
Status
Diagnosis
1
On
Indicates
−
25 volts DC is present on process control module PC4.
Off
Indicates
−
25 volts DC is not present on process control module PC4.
2
On
Ind25 volts DC is present on process control module PC4.
Off
Ind25 volts DC is not present on process control module PC4.
3,4
On
See Network Status Table in Section 9-12.
Off
See Network Status Table in Section 9-12.