background image

OM-1597 Page 8

1-4.

Principales normes de sécurité

Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Wel-
ding Society, 550 N.W. Lejeune Rd, Miami FL 33126

Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402.

Recommended Safe Practice for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances,
 norme AWS
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126

National Electrical Code, NFPA Standard 70, de la National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.

Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de l’Association canadienne de normalisation, vente de
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.

Safe Practices For Occupation And Educational Eye And Face Protec-
tion
, norme ANSI Z87.1, de l’American National Standards Institute,
1430 Broadway, New York, NY 10018.

Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.

1-5.

Information sur les champs électromagnétiques

Données sur le soudage électrique et sur les effets, pour l’organisme,
des champs magnétiques basse fréquence

Le courant de soudage, pendant son passage dans les câbles de sou-
dage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir ex-
aminé plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National Re-
search Council a conclu: “L’accumulation de preuves, suivant le
jugement du comité, n’a pas démontré que l’exposition aux champs
magnétiques et champs électriques à haute fréquence représente un
risque à la santé humaine”. Toutefois, des études sont toujours en cours
et les preuves continuent à être examinées. En attendant que les con-
clusions finales de la recherche soient établies, il vous serait
souhaitable de réduire votre exposition aux champs électromagnéti-
ques pendant le soudage ou le coupage.

Afin de réduire les champs électromagnétiques dans l’environnement
de travail, respecter les consignes suivantes :

1

Garder les câbles ensembles en les torsadant ou en les
attachant avec du ruban adhésif.

2

Mettre tous les câbles du côté opposé de l’opérateur.

3

Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.

4

Garder le poste de soudage et les câbles le plus loin possible de
vous.

5

Relier la pince de masse le plus près possible de la zone de
soudure.

Consignes relatives aux stimulateurs cardiaques :

Les personnes qui portent un stimulateur cardiaque doivent avant tout
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est
alors recommandé de respecter les consignes ci–dessus.

Содержание SWLL-115

Страница 1: ...R 115 SWSL 115 And SWLR 115E Processes Description OM 1597 192 710 November 1998 Automatic Welding Heavy Duty Wire Feeder For Automated Welding Applications Motor Drive Assemblies Visit our website at...

Страница 2: ...alue established in 1929 This Owner s Manual is designed to help you get the most out of your Miller products Please take time to read the Safety precautions They will help you protect yourself agains...

Страница 3: ...l installation le fonctionnement et la maintenance 7 1 4 Principales normes de s curit 8 1 5 Information sur les champs lectromagn tiques 8 SECTION 2 INSTALLATION 9 2 1 Specifications 9 2 2 Descriptio...

Страница 4: ......

Страница 5: ...that cord plug is connected to a properly grounded receptacle outlet D When making input connections attach proper grounding conduc tor first double check connections D Frequently inspect input power...

Страница 6: ...lding wire at contact tip when not in use D Wear oil free protective garments such as leather gloves heavy shirt cuffless trousers high shoes and a cap D Remove any combustibles such as a butane light...

Страница 7: ...aintained D Keep high frequency source doors and panels tightly shut keep spark gaps at correct setting and use grounding and shielding to minimize the possibility of interference ARC WELDING can caus...

Страница 8: ...s a human health hazard However studies are still going forth and evidence continues to be examined Until the final conclusions of the research are reached you may wish to minimize your exposure to el...

Страница 9: ...e de terre du sectionneur ou que la fiche du cordon est raccord e une prise correctement mise la terre D En effectuant les raccordements d entr e fixer d abord le conducteur de mise la terre appropri...

Страница 10: ...r des v tements de protection d pourvus d huile tels que des gants en cuir une chemise en mat riau lourd des pantalons sans re vers des chaussures hautes et un couvre chef D Avant de souder retirer to...

Страница 11: ...vrements et dispositifs de protection LE RAYONNEMENT HAUTE FR QUENCE H F risque de provoquer des interf rences D Le rayonnement haute frequence peut provoquer des interf rences avec les quipements de...

Страница 12: ...champs magn tiques basse fr quence Le courant de soudage pendant son passage dans les c bles de sou dage causera des champs lectromagn tiques Il y a eu et il y a encore un certain souci propos de tels...

Страница 13: ...0 To 210 ipm 0 To 5 3 mpm 1 8 To 7 32 in 3 2 To 5 6 mm 1 8 HP 70 RPM 115 VDC 1 5 A 17 in 0 43 m 17 1 2 lb 7 9 kg 2 2 Description 802 269 1 Motor drive Assembly This unit is a heavy duty wire feed ing...

Страница 14: ...41 B 11 1 2 292 C 5 3 4 146 Inches Millimeters A 4 1 4 108 B 4 1 4 108 C 7 16 Dia 11 1 Dia 4 Holes 4 Holes A B C A B C 2 4 Typical Equipment Location ST 131 138 A 1 Welding Power Source 2 Gas Cylinder...

Страница 15: ...ive Roll Remove drive rolls 5 Wire Guide Securing Screw Loosen wire guide screws 6 Anti Wear Guide 7 Inlet Wire Guide Install inlet wire guide into anti wear guide and secure with setscrew Install inl...

Страница 16: ...tightly to keep it from unraveling WIRE ADVANCE V Weld Control Welding Power Source Set switches Pull and hold wire cut off end Push wire thru guide up to drive rolls continue to hold welding wire Pr...

Страница 17: ...vice Clean Monthly OR Clean Drive Rolls 3 2 Brush Inspection And Replacement 802 269 S 0816 1 Motor 2 Brush Cap Remove brush cap 3 Brush Replace brush if it becomes chipped or broken or if less than 1...

Страница 18: ...iner See gun torch Owner s Manual Remove weld spatter or foreign matter from around gun torch nozzle opening Check and secure motor plug connection check brushes Have Factory Authorized Service Agent...

Страница 19: ...OM 1597 Page 15 SECTION 4 ELECTRICAL DIAGRAMS SA 192 940 Figure 4 1 Circuit Diagram For SWLR 115 SWLL 115 SWSR 115 And SWSL 115 SA 192 941 Figure 4 2 Circuit Diagram For SWLR 115E...

Страница 20: ...Roll Wire Guide Kits Hardware is common and not available unless listed 1 2 3 1 2 3 5 6 7 8 9 23 24 25 28 29 30 31 32 33 34 35 36 37 38 39 40 41 1 2 3 1 2 3 5 6 4 4 7 12 14 15 16 17 18 19 20 21 22 26...

Страница 21: ...200 WASHER lock stl split No 8 1 22 129 351 SCREW mach stl rdh 8 32 x 500 1 23 191 661 BRACKET right mount 1 23 191 662 BRACKET left mount 1 24 190 168 INSULATOR BOARD glastic 1 25 190 169 FACEPLATE...

Страница 22: ...m 151 056 5 64 in 5 64 in 079 in 2 0 mm 151 057 3 32 in 3 32 in 094 in 2 4 mm 151 058 7 64 in 7 64 in 110 in 2 8 mm 151 059 1 8 in 1 8 in 125 in 3 2 mm 151 060 5 32 in 5 32 in 156 in 4 0 mm 3 16 in 3...

Страница 23: ...ting Torches Remote Controls Accessory Kits Replacement Parts No labor Spoolmate 185 Spoolmate 250 Canvas Covers Miller s True Blue Limited Warranty shall not apply to 1 Consumable components such as...

Страница 24: ...complete and retain with your personal records Always provide Model Name and Serial Style Number Call 1 800 4 A Miller or see our website at www MillerWelds com to locate a DISTRIBUTOR or SERVICE AGEN...

Отзывы: