A complete Parts List is available at www.MillerWelds.com
OM-242 880 Page 27
Ref. 803 640-A / 801 400-B
5-5. Sequence Of Gouging Operation
Connect work clamp to a clean, paint-free
location on workpiece, as close to cutting
area as possible.
Raise trigger lock and press trigger. Pilot
arc starts and will go out after 3 seconds if
gouging arc is not established. Move tip to
within approximately 3/16 in (4.8 mm). Start
gouging across workpiece surface. Maintain
approximately a 45
°
angle to surface.
Release trigger. Postflow continues after
releasing trigger; arc can be instantly
restarted during postflow by raising trigger
lock and pressing trigger.
!
The pilot arc starts immediately
when trigger is pressed.
Hold torch at approximately
45
°
angle to workpiece.
45
5
.
Unit automatically regulates pressure to 60 psi
(413 kPa) for gouging.
CUT
GOUGE
.
Connect work clamp to portion of workpiece
that does not fall away after being cut.
.