A complete Parts List is available at www.MillerWelds.com
OM-242 880 Page 32
6-5. +24 Volts DC Hot Contacts For Isolated Input Module Operation
243 336-A / 804 041-A
!
Turn off power source and
disconnect input power.
Remove wrapper (see Section 7-4).
Control board PC1 can 24
volts DC from receptacle RMT2 to
operate a customer-supplied
isolated input module for the Okay
To Move signal.
1
Control Board PC1
2
Receptacle RMT1
3
Receptacle RMT2
4
Receptacle RC61
Move plug from RMT1 into
receptacle RMT2 on PC1. Be
sure remote control cable plug is
connected to RC61 on rear of
unit.
If voltage sensing is required, see
Section 6-8.
Install wrapper on unit.
Required Items:
Customer-supplied isolated input
module.
.
Machine torch equipped
plasma cutter is shipped from
the factory with plug connected
to receptacle RMT1 (dry
contacts).
Tools Needed:
Remote Control Cable
Remote
Start
White
Red
Black
Green
+24 VDC
Output
Okay To
Move
+
−
.
+24 volts DC will activate relay coil after unit is triggered and
the cutting arc is initiated.
1
3
2
4
Torx 25
Содержание CE-60T