23
NOTE: This setting will work if you are using CLOSED POSITION STOP PLATES
but WILL NOT work if you are using a LOCK
BOTH OPERATORS OPEN SIMULTANEOUSLY
SECOND OPERATOR CLOSES FIRST
SEQ1 = OFF SEQ2 = OFF (factory setting)
If both SEQ1 and SEQ2 are set to OFF, the FIRST OPERATOR and SECOND
OPERATOR open simultaneously. The SECOND OPERATOR will close first.
NOTE: This is the setting you need to use with
CLOSED POSITION STOP PLATES and/or LOCK
FIRST OPERATOR OPENS FIRST,
SECOND OPERATOR CLOSES FIRST
SEQ1 = OFF SEQ2 = ON
If SEQ1 is set to OFF, and SEQ2 is set to ON, the FIRST OPERATOR will open
first, and the SECOND OPERATOR will close first.
NOTE: This setting can not be used if you are using
CLOSED POSITION STOP PLATES or a LOCK
FIRST OPERATOR OPENS FIRST,
FIRST OPERATOR CLOSES FIRST
SEQ1 = ON SEQ2 = ON
If SEQ1 is set to ON, and SEQ2 is set to ON, The FIRST OPERATOR opens and
closes first.
NOTE: This setting can not be used if you are using
CLOSED POSITION STOP PLATES or a LOCK
BOTH OPERATORS OPEN SIMULTANEOUSLY
BOTH OPERATORS CLOSES SIMULTANEOUSLY
SEQ1 = ON SEQ2 = OFF
If SEQ1 is set to ON, and SEQ2 is set to OFF, the FIRST OPERATOR and
SECOND OPERATOR open and close simultaneously.
Replace the control box cover and fasten it with (4) screws. Turn the
control box power switch ON. The system will energize in approximately
15 seconds.
1234
ON
OBSTRUCT
SENS.
PULL/PUSH
SEQ1
SNGL/DUAL
SEQ2
MIN
MAX
LEARN
1234
ON
OBSTRUCT
SENS.
PULL/PUSH
SEQ1
SNGL/DUAL
SEQ2
MIN
MAX
LEARN
1234
ON
OBSTRUCT
SENS.
PULL/PUSH
SEQ1
SNGL/DUAL
SEQ2
MIN
MAX
LEARN
1234
ON
OBSTRUCT
SENS.
PULL/PUSH
SEQ1
SNGL/DUAL
SEQ2
MIN
MAX
LEARN
DIP Switch Settings for Gate Sequencing