WARNING AND SAFETY INSTRUCTIONS
12
Heat pump technology and refrigerant:
The heat pump in this tumble dryer uses a gaseous refrigerant which
is condensed by the compressor. The refrigerant, which is brought to
a higher temperature level and liquefied by condensing, is led in a
closed circuit through the heat exchanger unit where heat exchange
with the circulating drying air takes place.
Damage to the tumble dryer by switching it on too soon.
This can damage the heat pump.
After setting up the tumble dryer, wait for at least one hour before
starting a drying program.
- The humming noises caused by the heat pump during the drying
process are normal. They do not impair the efficient functioning of
the tumble dryer.
- The refrigerant is not flammable or explosive.
- This tumble dryer contains fluorinated greenhouse gases.
Hermetically sealed.
Designation of refrigerant: R134a
Amount of refrigerant: 0,47 kg
Global warming potential of refrigerant: 1430 kg CO
2
e
Global warming potential of appliance: 672 kg CO
2
e
This product can contain chemicals known by the state of
California to cause cancer, birth defects and other genetic defects.
Содержание TXR 860 WP
Страница 100: ...M Nr 11 677 050 01 en CA TXR 860 WP ...