* For appliances with installed wall
spacers, the appliance depth
increases by 35 mm.
a
Overhead cabinet
b
Appliance
c
Kitchen cabinet
d
Wall
This appliance can be installed in any
array of kitchen units. To ensure a
uniform height over the entire array, a
suitable overhead cabinet
a
can be
installed above the appliance.
A ventilation channel with a depth of at
least 50 mm must be provided across
the entire width of the overhead cabinet
to guarantee proper air circulation.
The cross section of the air outlet below
the room's ceiling must be at least
300 cm
2
to allow warm air to escape
unhindered. Otherwise, the compressor
will have to work harder, which
increases energy consumption.
The ventilation openings must not
be covered or blocked in any way.
They should also be dusted on a
regular basis.
When built into an array featuring
normed kitchen cabinets (max. depth of
580 mm), the appliance can be
installed directly next to the kitchen
cabinet unit. The appliance door will
then protrude past the front of the
cabinet by 34 mm* on the sides and
55 mm* in the middle. This allows the
door to be opened and closed without
any interference.
If the appliance is installed next to a
wall
d
, a gap of at least 55 mm
between the wall
d
and the appliance
b
is necessary on the hinge side. This
distance is equal to the handle
projection when the door is open.