Problem solving guide
99
Water inlet fault
Issue
Cause and remedy
The warning buzzer is
sounding.
One of the following
messages appears in
the display:
Open stopcock
The stopcock is closed.
Open the stopcock fully.
Water intake
Before rectifying the problem:
Switch the dishwasher off.
The water inlet is restricted.
Open the stopcock fully and start the programme
again.
Clean the filter in the water inlet (see “Cleaning
and care” – Cleaning the filter in the water inlet”).
The water-connection pressure is lower than
50 kPa.
Seek professional advice.
The on-site connection for the water drainage may
be too low and you will need to vent the water
drainage (see “Installation – Water drainage”).
Fault F18
A technical fault has occurred.
Switch the dishwasher off.
Close the stopcock.
Call the Miele Customer Service Department.
The following fault
message appears on
the display during the
SolarSave
programme:
Intake temperature too low
The intake water has not reached the required
temperature of 45 °C (see “Installation – Water inlet”).
Start the programme again.
If the fault message appears again, select a
different programme.
Содержание HG07-W
Страница 59: ...Loading the dishwasher 59 Loading examples Dishwashers with cutlery tray Upper basket Lower basket ...
Страница 60: ...Loading the dishwasher 60 Cutlery tray Heavily soiled items ...
Страница 120: ......
Страница 121: ......
Страница 122: ......
Страница 124: ...M Nr 11 708 050 00 en SA G 7310 G 7312 G 7315 G 7317 G 7322 G 7327 ...