![background image](http://html.mh-extra.com/html/miele/b-890/b-890_technical-information_235716041.webp)
Technical Information
41
B 890/B 990
Figure 050-2:
Control Electronic A1
3
Fault Repair
3.1
Noisy Operation in the Bearing Flange
Cause:
Lubricant (grease or oil) in the bearing.
Remedy:
1. Remove the bearing flange; see Section 050-4.3.
2. Remove lubricant (grease or oil) from the bearing.
4 Service
4.1
Control Electronic (A1) Removal
Note:
From machine no. 46641397, a new control panel was installed. The old
control panel (mat. no. 5056071) must always be replaced with an old
version and the new panel (mat. no. 5368000) must be replaced with a new
version.
1. Tilt the ironing table to its horizontal position; see Section 020-4.1.
2. Lever off the switch knob using a lid opener or yellow Miele tool.
3. Remove the T20 screw from the rear of the control electronic cover.
4. Lift the cover at the rear and unclip it at the front.
5. Disconnect all connections from the control electronic.
6. Remove the cover/electronic assembly.
Содержание B 890
Страница 1: ...TECHNICAL INFORMATION B 890 and B 990 Rotary Irons US Models 2011 Miele USA ...
Страница 11: ...Technical Information 11 B 890 B 990 010 Stand ...
Страница 21: ...Technical Information 21 B 890 B 990 020 Heater Plate ...
Страница 28: ...Technical Information 28 B 890 B 990 030 Heater Plate Motor ...
Страница 32: ...Technical Information 32 B 890 B 990 035 Lifting Arm ...
Страница 34: ...Technical Information 34 B 890 B 990 Figure 035 1 Leaf Spring and Holder 4 1 2 3 ...
Страница 35: ...Technical Information 35 B 890 B 990 040 Roller ...
Страница 39: ...Technical Information 39 B 890 B 990 050 Roller Motor ...