![Miele B 890 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/miele/b-890/b-890_technical-information_235716016.webp)
Technical Information
16
B 890/B 990
necessary, and then feed the Bowden cable/spring assembly as far down
the stand as possible. Pull the twine or cord through the bottom of the
stand and tie or tape it down.
14. Grab the J-hook with pliers and reattach it to the base.
15. Check for smooth operation by unlocking the ironing table and moving it
to the stowed (vertical) position; if binding or unusual noises occur,
unhook the spring and check that the Bowden cable is centered on its
pulley.
16. If operation is smooth, re-install the main electronic cover and secure it
with the T20 screw.
Note:
When the cable guide (plastic “neck”) on the cover pushes against the hinge
after reassembly, the cover can break when the iron is folded.
4.3 Transformer
Removal
1. Tilt the ironing table to its horizontal position; see Section 020-4.1.
2. Lay the iron on its back, on a mat or blanket to prevent scratching.
3. Tie a sturdy cord (such as twine) to the J-hook at the bottom of the spring.
4. Release tension from the Bowden cable by disconnecting the tension
spring. Grab the J-hook at the bottom of the spring with pliers and pull it
off of the base to disengage the spring.
Warning!
With the spring disconnected, movement of the ironing table will be
unrestricted because there is no tension holding it in place.
5. Bring the iron to its upright, stowed position (see the operating manual).
6. Remove the main electronic's cover (T20 screw) from the stand (Figure
010-3, Item 1).
7. Remove the T20 screw securing the main electronic to the stand (Figure
010-4, Item 1).
8. Slide the main electronic out of the stand.
9. Disconnect the transformer and foot switch wiring harnesses (all Molex)
from the main electronic.
10. Lay the iron on its back again.
11. Remove the four T30 bolts from the underside of the base.
12. Carefully remove the base.
13. Disconnect the 2 Molex plugs from the transformer.
14. Remove the 2 Phillips screws securing the transformer to its mounting
bracket.
15. Remove the transformer from its mounting bracket.
4.4
Transformer Replacement, Base/Stand Reassembly
1. Bring the iron to its upright, stowed position (see the operating manual).
2. Lay the iron on its back, on a mat or blanket to prevent scratching.
3. Secure the new transformer to the mounting bracket with the 2 Phillips
screws and reconnect the 2 Molex connections.
4. Feed the transformer and foot switch wiring harnesses back through the
Содержание B 890
Страница 1: ...TECHNICAL INFORMATION B 890 and B 990 Rotary Irons US Models 2011 Miele USA ...
Страница 11: ...Technical Information 11 B 890 B 990 010 Stand ...
Страница 21: ...Technical Information 21 B 890 B 990 020 Heater Plate ...
Страница 28: ...Technical Information 28 B 890 B 990 030 Heater Plate Motor ...
Страница 32: ...Technical Information 32 B 890 B 990 035 Lifting Arm ...
Страница 34: ...Technical Information 34 B 890 B 990 Figure 035 1 Leaf Spring and Holder 4 1 2 3 ...
Страница 35: ...Technical Information 35 B 890 B 990 040 Roller ...
Страница 39: ...Technical Information 39 B 890 B 990 050 Roller Motor ...