Technical Information
6
B 890/B 990
2
Touch Current Measurement
Note:
Touch current measurement should be carried out on all accessible
conductive parts that are not connected to ground.
Warning!
Touch current measurement should only be carried out after the ground
connection of the appliance under test has been checked and found to be
satisfactory!
Dangerous voltages may exist on defective machines as well as on
accessible conductive parts that are not connected to ground!
Note:
No touch current measurement is necessary.
3
Risk of Injury Due to Tilting Mechanism
Warning!
When working on the appliance, the table and stand may tilt together/apart
unintentionally and this could cause injury.
The ironing table and stand are linked via a tilting mechanism. In its
transport (upright) position, the tilting mechanism is under tension; in its
working (horizontal) position, the tension in the table spring is released.
Before working on the appliance, tilt the ironing table into the working
(horizontal) setting and lock it in place.
When working under the ironing table, tilt the complete appliance
onto its back.
B Modification
History
When Who
What
3/8/2011
Jessica Naples
Conversion for Website
11/10/2008 Liane
Westerhelweg Version
4
8/19/2008 Liane
Westerhelweg Version
3
11/20/2003
Olaf Meyer zu Drewer
Version 2
6/29/1999
Jürgen Peller
Version 1
Содержание B 890
Страница 1: ...TECHNICAL INFORMATION B 890 and B 990 Rotary Irons US Models 2011 Miele USA ...
Страница 11: ...Technical Information 11 B 890 B 990 010 Stand ...
Страница 21: ...Technical Information 21 B 890 B 990 020 Heater Plate ...
Страница 28: ...Technical Information 28 B 890 B 990 030 Heater Plate Motor ...
Страница 32: ...Technical Information 32 B 890 B 990 035 Lifting Arm ...
Страница 34: ...Technical Information 34 B 890 B 990 Figure 035 1 Leaf Spring and Holder 4 1 2 3 ...
Страница 35: ...Technical Information 35 B 890 B 990 040 Roller ...
Страница 39: ...Technical Information 39 B 890 B 990 050 Roller Motor ...