8. Power supply connection

Gasket must be properly  

positioned to create seal

Checking the gasket

Check that the gasket is properly positioned inside the lid, then close the junction box.

Secure it with 2 countersunk screws (gradually tighten them, do not tighten sequentially).

WARNING: if the gasket is wrongly positioned or screws are loose, water may get into the junction 
box.

Place the cover back on the driver unit and the cap on the control plug if not needed.

9. Control connection DALI

Strip the rubber jacket of the cable, expose 25 mm of 
conductors. Mount the TH384 – socket connector.  
Match  
L  

 

RED conductor (+ pole / DA+) 

 

BLUE conductor (- pole / DA-). 

Tighten the screws and pull each wire to check if they are 
well clamped. Conductor colors may vary.

Remove the plastic cap to plug the control cable (2 poles, 
yellow connector).

Insert the socket into the connector housing. Tighten the 
plastic nut to seal the cable with the connector grommet.

25

Содержание Modus R 1000

Страница 1: ...6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 Modus R 1000 INSTALLATION GUIDANCE v1 0 ...

Страница 2: ... This user manual contains important information on safe operation of the Luminaire Read and follow all safety notes and all instructions Save this manual for future reference Make sure that it is available to all persons using this device All wiring should be done by a licensed electrician in accordance with state codes local codes and National Electric Code NEC standards or International Electro...

Страница 3: ...t to be placed face down on any surface other than the provided foam pad Risk of electric shock Disconnect the electrical power supply before commencing the installation failure to do so could result in serious injury Hard Hats Safety shoes Hi Vis vest and Safety Gloves must be worn at all times Do not use a generator Two persons required to complete the installation 1m Waiver This document repres...

Страница 4: ...d correlated subsequent ones medium x 0 1 0 2 0 3 0 5 0 8 1 2 2 3 Shaft h11 coarse 0 2 0 5 0 8 1 2 2 3 4 5 Holes H11 Tolerance class up to 6 over 6 up to 30 over 30 up to120 over 120 up to315 over 315 up to1000 over 1000 up to2000 over 2000 up to4000 over 4000 Lead screws 6H Screws 6g ISO Metric Screw DIMENSIONS WITHOUT TOLERANCE DEGREE 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 6 7 8 9 ...

Страница 5: ...EE DETAIL A 7 Floodlight connection 7a Floodlight connection with an IP68 connector Unscrew the cover Unscrew the 4 x M5 screws Then remove the plastic cap from the connector plug push towards the connector side and remove the cover Connecting via cable gland Remove the 2 countersunk screws to remove the junction box lid Insert the cable for the floodlight through the cable gland Remove the cable ...

Страница 6: ...cket has L N earth symbols Match as follows Live BROWN wire Neutral BLUE wire Earth symbol YELLOW GREEN wire Insert the exposed wires in the plug and tighten each screw Pull the wires to check if they are well tightened SCALE 2 1 XSEC0001 XSEC0001 SECTION 7a Floodlight connection with an IP68 connector Inserting the cable with plug connector into the floodlight junction box To connect the accessor...

Страница 7: ...ng installation Do not bend the cables more than the minimum bending radius 5 to 8 times of the diameter of the cable Connecting the WAGO terminals Insert the cable with the connector through the cable gland and connect its wires to the wago terminals as follows BROWN wire that has the sticker BLUE wire that has the sticker YELLOW GREEN GND YELLOW GREEN wire Firmly tighten the cable gland close th...

Страница 8: ...nector through the cable gland and connect its wires to the wago terminals as follows BROWN wire that has the sticker BLUE wire that has the sticker YELLOW GREEN GND YELLOW GREEN wire Firmly tighten the cable gland close the junction box lid and mount the junction box cover back in position Make sure everything is properly tightened 7b Floodlight connection without a connector To the lid To the li...

Страница 9: ...e is no wire connected 51 60 PRODUCED BY AN AUTODESK STUDENT VERSION PRODUCED BY AN AUTODESK STUDENT VERSION PRODUCED BY AN AUTODESK STUDENT VERSION PRODUCED BY AN AUTODESK STUDENT VERSION DRIVER OUTPUT CABLE DRIVER INPUT CABLE OUTPUT CABLE to floodlight MAINS CABLE TO LID Remove the cable sheath for a length of 60 mm expose the conductor for 9 mm and insert the mains cable through the cable gland...

Страница 10: ...screws are loose water may get into the junction box Place the cover back on the driver unit and the cap on the control plug if not needed 9 Control connection DALI Strip the rubber jacket of the cable expose 25 mm of conductors Mount the TH384 socket connector Match L RED conductor pole DA N BLUE conductor pole DA Tighten the screws and pull each wire to check if they are well clamped Conductor c...

Страница 11: ...und OUTPUT cable this cable power supplies the floodlight This cable has 2 wires brown and blue The connection must be done in such a way that the 2 wires match these poles on the floodlight connector on the top of the mast Brown L or if you don t use the IP68 connector Blue N or if you don t use the IP68 connector CONTROL cable this cable controls floodlight output through the control system This...

Страница 12: ...k Modus R 1000 Floodlight Modus R Outdoor driver cabinet driver is the same without metalwork 280 x 230 x 76 mm 478 432 593 398 152 230 182 202 176 16 96 2 30 90 17 21 SCALE 1 5 478 432 593 398 152 230 182 202 176 16 96 2 30 90 17 21 SCALE 1 5 478 432 593 398 152 230 182 202 176 16 96 2 30 90 17 21 SCALE 1 5 When you need to install multiple Midstream remote drivers and different models of floodli...

Страница 13: ...ing com installation guides European HQ Midstream Ltd Wessex House 1 Chesham Street London SW1X 8ND United Kingdom Telephone 44 207 584 8310 Email info midstreamlighting com US HQ Midstream Lighting Ltd 66 West Flagler Street Miami FL 33130 USA Telephone 888 549 6775 Email info midstreamlighting com midstreamlighting com ...