MODUS R 1000 INSTALLATION GUIDANCE
10. Control connection 0-10V
Strip the rubber jacket of the cable, expose 25 mm of
conductors. Mount the TH384 – socket connector.
Match
Remove the plastic cap to plug the control cable (3 poles,
white connector).
Insert the socket into the connector housing. Tighten the plastic nut to seal the cable with the connector
grommet.
25
Dim
+
Dim
-
12v
11. Cabinet driver
Outdoor layout
Cabinet layout
Input cable (mains)
Output cable
Control cable
INPUT cable: this cable power supplies the driver. Its 3 wires must match these connections:
Brown
L / L1
Blue
N / L2
Yellow & Green
Ground
OUTPUT cable: this cable power supplies the floodlight. This cable has 2 wires: brown (+) and blue (-). The connection
must be done in such a way that the 2 wires match these poles on the floodlight connector on the top of the mast:
Brown
L (or + if you don't use the IP68 connector)
Blue
N (or - if you don't use the IP68 connector)
CONTROL cable: this cable controls floodlight output through the control system. This cable has 3 wires: purple
(d), grey (dimming - ) and black & white (12V aux). The connection has to be done in such a way that the 3
wires match these poles inside your cabinet:
Purple
D
Grey
Dimming -
Black & White
12 V Auxiliary output voltage (only if needed)
L
BROWN conductor
(D pole)
N
BLUE conductor
(Dimming - pole)
Ground pole
12 V aux wire
Tighten the screws and pull each wire to check if they are
well clamped. Conductor colours may vary.