background image

3

midstreamlighting.com   call +44 (0) 207 584 8310

MODUS R 1000 INSTALLATION GUIDANCE

2

Contents

Prior to starting the installation, check the equipment list 
to be sure of using the correct tools (mounting screw(s) 
and nut(s) are not supplied).

  24 mm standard wrench for M16 screws

  30 mm standard wrench for M20 screws

  #8 allen key

  Powered drill-screwdriver with adjustable  

 

torque (clutch)

  Torx T25 insert bit for powered screwdriver (to be  

 

used with M5 screws)

  Torx T25 manual screwdriver

  Torx T30 insert bit for powered screwdriver (to be  

 

used with M6 screws)

  Torx T30 manual screwdriver

  Monkey pliers

  Electrician scissors for wires

  Ph2 screwdriver

  Slotted manual screwdriver for connector’s     

   screws (blade dimensions: 3.5(w) x 0.6(t)mm)

  Wire stripping pliers

DO NOT USE PERCUSSION DRILLS!

Equipment list

 

Wear adequate working gloves, safety shoes and  

 

hard hats to protect yourself from falling material

 

Never energize the lamp if wiring operation are not  

 completed

H&S check

1. General notes

Section  

PAGE

1   General notes 

3

2   Safety instructions 

4

3   Contents 

5

4   Bracket mounting and aiming  

6

Visor mounting 

7

Electrical connection 

7

Floodlight connection 

8

7a  Floodlight connection with connector 

9

7b  Floodlight connection without connector 

14 

 

Power supply connection 

17

Control connection Dali 

19

10  Control connection 0-10V 

20

11  Cabinet driver 

21

This user manual contains important information on safe operation of the Luminaire.

Read and follow all safety notes and all instructions. Save this manual for future reference.

Make sure that it is available to all persons using this device.

All wiring should be done by a licensed electrician in accordance with state codes, local codes, and National Electric 
Code (NEC) standards or International Electrotechnical Commission (IEC) standards.

The Luminaire is suitable for wet locations.

This luminaire must only be replaced by the manufacturer, by its service staff or by qualified personnel.

The luminaire is suitable for outdoor use

IP66:

 The product is protected against powerful water jets.

DO

  Store the luminaire with care, avoiding placing the lenses on the ground, which may scratch or damage them

  Keep the luminaire in the original packaging when storing to avoid damage

  When handling the Luminaire, wear industrial safety gloves and safety boots

  Operate on circuitry when the electrical power supply is disconnected

DO NOT

 

Apply  mains  voltage  through  the  control  system  cable.  This  will  damage  the  luminaire  and  it  will  no  longer  be                                                                                                                                               

       covered by warranty

 

Unnecessarily remove the luminaire from the box

 

Leave the LED luminaire switched on when resting on the ground with optics facing down

 

Place the luminaire with the lens on the ground, dirty or metal surfaces

 

Clean the lenses with any industrial detergent. Use a water-soaked cloth if needed

12  Driver/floodlight pairing 

22

13  Electrical specifications 

22

14  Weight and Windage  

22

15 Dimensions 

23

Содержание Modus R 1000

Страница 1: ...6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 Modus R 1000 INSTALLATION GUIDANCE v1 0 ...

Страница 2: ... This user manual contains important information on safe operation of the Luminaire Read and follow all safety notes and all instructions Save this manual for future reference Make sure that it is available to all persons using this device All wiring should be done by a licensed electrician in accordance with state codes local codes and National Electric Code NEC standards or International Electro...

Страница 3: ...t to be placed face down on any surface other than the provided foam pad Risk of electric shock Disconnect the electrical power supply before commencing the installation failure to do so could result in serious injury Hard Hats Safety shoes Hi Vis vest and Safety Gloves must be worn at all times Do not use a generator Two persons required to complete the installation 1m Waiver This document repres...

Страница 4: ...d correlated subsequent ones medium x 0 1 0 2 0 3 0 5 0 8 1 2 2 3 Shaft h11 coarse 0 2 0 5 0 8 1 2 2 3 4 5 Holes H11 Tolerance class up to 6 over 6 up to 30 over 30 up to120 over 120 up to315 over 315 up to1000 over 1000 up to2000 over 2000 up to4000 over 4000 Lead screws 6H Screws 6g ISO Metric Screw DIMENSIONS WITHOUT TOLERANCE DEGREE 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 6 7 8 9 ...

Страница 5: ...EE DETAIL A 7 Floodlight connection 7a Floodlight connection with an IP68 connector Unscrew the cover Unscrew the 4 x M5 screws Then remove the plastic cap from the connector plug push towards the connector side and remove the cover Connecting via cable gland Remove the 2 countersunk screws to remove the junction box lid Insert the cable for the floodlight through the cable gland Remove the cable ...

Страница 6: ...cket has L N earth symbols Match as follows Live BROWN wire Neutral BLUE wire Earth symbol YELLOW GREEN wire Insert the exposed wires in the plug and tighten each screw Pull the wires to check if they are well tightened SCALE 2 1 XSEC0001 XSEC0001 SECTION 7a Floodlight connection with an IP68 connector Inserting the cable with plug connector into the floodlight junction box To connect the accessor...

Страница 7: ...ng installation Do not bend the cables more than the minimum bending radius 5 to 8 times of the diameter of the cable Connecting the WAGO terminals Insert the cable with the connector through the cable gland and connect its wires to the wago terminals as follows BROWN wire that has the sticker BLUE wire that has the sticker YELLOW GREEN GND YELLOW GREEN wire Firmly tighten the cable gland close th...

Страница 8: ...nector through the cable gland and connect its wires to the wago terminals as follows BROWN wire that has the sticker BLUE wire that has the sticker YELLOW GREEN GND YELLOW GREEN wire Firmly tighten the cable gland close the junction box lid and mount the junction box cover back in position Make sure everything is properly tightened 7b Floodlight connection without a connector To the lid To the li...

Страница 9: ...e is no wire connected 51 60 PRODUCED BY AN AUTODESK STUDENT VERSION PRODUCED BY AN AUTODESK STUDENT VERSION PRODUCED BY AN AUTODESK STUDENT VERSION PRODUCED BY AN AUTODESK STUDENT VERSION DRIVER OUTPUT CABLE DRIVER INPUT CABLE OUTPUT CABLE to floodlight MAINS CABLE TO LID Remove the cable sheath for a length of 60 mm expose the conductor for 9 mm and insert the mains cable through the cable gland...

Страница 10: ...screws are loose water may get into the junction box Place the cover back on the driver unit and the cap on the control plug if not needed 9 Control connection DALI Strip the rubber jacket of the cable expose 25 mm of conductors Mount the TH384 socket connector Match L RED conductor pole DA N BLUE conductor pole DA Tighten the screws and pull each wire to check if they are well clamped Conductor c...

Страница 11: ...und OUTPUT cable this cable power supplies the floodlight This cable has 2 wires brown and blue The connection must be done in such a way that the 2 wires match these poles on the floodlight connector on the top of the mast Brown L or if you don t use the IP68 connector Blue N or if you don t use the IP68 connector CONTROL cable this cable controls floodlight output through the control system This...

Страница 12: ...k Modus R 1000 Floodlight Modus R Outdoor driver cabinet driver is the same without metalwork 280 x 230 x 76 mm 478 432 593 398 152 230 182 202 176 16 96 2 30 90 17 21 SCALE 1 5 478 432 593 398 152 230 182 202 176 16 96 2 30 90 17 21 SCALE 1 5 478 432 593 398 152 230 182 202 176 16 96 2 30 90 17 21 SCALE 1 5 When you need to install multiple Midstream remote drivers and different models of floodli...

Страница 13: ...ing com installation guides European HQ Midstream Ltd Wessex House 1 Chesham Street London SW1X 8ND United Kingdom Telephone 44 207 584 8310 Email info midstreamlighting com US HQ Midstream Lighting Ltd 66 West Flagler Street Miami FL 33130 USA Telephone 888 549 6775 Email info midstreamlighting com midstreamlighting com ...

Отзывы: