14
15
midstreamlighting.com call +44 (0) 207 584 8310
MODUS R 1000 INSTALLATION GUIDANCE
7b. Floodlight connection without a connector
Inserting the cable into the floodlight junction box
To directly wire the floodlight head using the cable coming directly from driver’s output side, remove the junction box
cover and the junction box lid. Loosen the cable gland with the plastic cap and remove it
Connecting the WAGO terminals
Insert the cable with the connector through the cable gland and connect its wires to the wago terminals as follows:
BROWN (+)
wire that has the + sticker
BLUE (-)
wire that has the - sticker
YELLOW&GREEN (GND)
YELLOW&GREEN wire
Firmly tighten the cable gland, close the junction box lid, and mount the junction box cover back in position. Make sure
everything is properly tightened.
7b. Floodlight connection without a connector
To the lid
To the lid
The cable coming directly from
the drivers OUTPUT
Warning
Do not pull the cables during
installation. Do not bend the
cables more than the minimum
bending radius - 5 to 8 times of
the diameter of the cable.
Floodlight Junction Box
Floodlight Junction Box