V6-i VRF 50Hz
22
Midea
V
6
-i
Series E
ng
inee
ring Da
ta Boo
k
1
Specifications
Table 2-1.1: 7/8/9HP specifications
HP
7
8
9
Model name
MVi-200WV2RN1(A)
MVi-224WV2RN1(A)
MVi-260WV2RN1(A)
Power supply
V/Ph/Hz
380-415/3/50
Cooling
1
Capacity
kW
20
22.4
26.0
Power input
kW
5.28
6.77
10.04
EER
3.79
3.31
2.59
Heating
2
(Rated)
Capacity
kW
20
22.4
26.0
Power input
kW
4.43
5.42
6.86
COP
4.51
4.13
3.79
Heating
3
(Max.)
Capacity
kW
22.5
25.0
28.5
Power input
kW
5.95
6.67
7.70
COP
3.78
3.75
3.70
Connected
indoor unit
Total capacity
50-130% of outdoor unit capacity
Maximum quantity
11
13
15
Compressor
Type
DC inverter rotary
Quantity
1
Oil type
RB75EA
Start-up method
Soft start
Fan
Type
Propeller
Motor type
DC
Quantity
2
Motor output
kW
0.17×2
0.17×2
0.17×2
Air flow rate
m
3
/h
9000
9000
10000
Drive type
Direct
Refrigerant
Type
R410A
Factory charge
kg
6.5
6.5
6.5
Pipe
connections
4
Liquid pipe
mm
Ф9.53
Ф9.53
Ф9.53
Gas pipe
mm
Ф19.1
Ф19.1
Ф22.2
Sound pressure level
5
dB(A)
58
58
59
Sound power level
5
dB(A)
78
78
78
Net dimensions (W×H×D)
mm
1120×1558×528
Packed dimensions (W×H×D)
mm
1270×1720×565
Net weight
kg
143
143
144
Gross weight
kg
159
159
160
Ambient Temp.
operation
range
Cooling
o
C
-5~48
Heating
o
C
-20~24
Notes:
1. Indoor temperature 27°C DB, 19°C WB; outdoor temperature 35°C DB; equivalent refrigerant piping length 7.5m with zero level difference.
2. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference.
3. Indoor temperature 20°C DB; outdoor temperature 7°C DB, 6°C WB; equivalent refrigerant piping length 7.5m with zero level difference.
4. Diameters given are those of the unit's stop valves.
5. Sound pressure level is measured at a position 1m in front of the unit and 1m above the floor in a semi-anechoic chamber.