V6-i VRF 50Hz
55
P
art
2
- O
ut
do
or
Unit
Engineer
ing Da
ta
Table 2-8.5: MVi-335WV2RN1(A) cooling capacity (continued)
Combination
(%)
(Capacity
index)
Outdoor
temperature
(°C DB)
Indoor temperature(°C DB/WB)
DB:20.8,WB:14
DB:23.3,WB:16
DB:25.8,WB:18
DB:27,WB:19
DB:28.2,WB:20
DB:30.7,WB:22
DB:32,WB:24
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
50%
-5
11.42
1.82
13.65
1.98
15.83
2.19 16.92 3.00 18.34
3.11
20.86
3.54 22.48 3.81
-2
11.42
1.85
13.65
2.01
15.83
2.22 16.92 3.07 18.34
3.17
20.86
3.59 22.48 3.87
0
11.42
1.87
13.65
2.03
15.83
2.25 16.92 3.08 18.34
3.20
20.86
3.65 22.48 3.93
2
11.42
1.89
13.65
2.06
15.83
2.28 16.92 3.10 18.34
3.26
20.86
3.66 22.48 4.01
4
11.42
1.91
13.65
2.10
15.83
2.32 16.92 3.10 18.34
3.33
20.86
3.75 22.48 4.11
6
11.42
1.95
13.65
2.13
15.83
2.36 16.92 3.13 18.34
3.39
20.86
3.81 22.48 4.23
8
11.42
1.98
13.65
2.17
15.83
2.42 16.92 3.14 18.34
3.43
20.86
3.87 22.48 4.37
10
11.42
2.02
13.65
2.21
15.83
2.46 16.92 3.11 18.34
3.53
20.86
3.97 22.48 4.43
12
11.42
2.06
13.65
2.26
15.83
2.51 16.92 3.13 18.34
3.60
20.86
4.04 22.48 4.50
14
11.42
2.11
13.65
2.31
15.83
2.56 16.92 3.15 18.34
3.66
20.86
4.11 22.48 4.59
16
11.42
2.15
13.65
2.36
15.83
2.62 16.92 3.15 18.34
3.71
20.86
4.19 22.48 4.66
18
11.42
2.19
13.65
2.41
15.83
2.66 16.92 3.17 18.34
3.78
20.86
4.26 22.48 4.75
20
11.42
2.24
13.65
2.49
15.83
2.72 16.92 3.32 18.34
3.85
20.86
4.33 22.48 4.84
21
11.42
2.26
13.65
2.59
15.83
2.77 16.92 3.49 18.34
3.88
20.86
4.38 22.48 4.89
23
11.42
2.41
13.65
2.80
15.83
2.98 16.92 3.72 18.34
3.96
20.86
4.45 22.48 5.00
25
11.42
2.59
13.65
3.02
15.83
3.19 16.92 3.96 18.34
4.08
20.86
4.68 22.48 5.33
27
11.42
2.76
13.65
3.25
15.83
3.42 16.92 4.27 18.34
4.33
20.86
4.98 22.48 5.69
29
11.42
2.96
13.65
3.49
15.83
3.66 16.92 4.40 18.34
4.61
20.86
5.30 22.48 6.06
31
11.42
3.16
13.65
3.74
15.83
3.91 16.92 4.69 18.34
4.89
20.86
5.63 22.48 6.45
33
11.42
3.37
13.65
4.01
15.83
4.18 16.92 4.94 18.34
5.19
20.86
5.99 22.48 6.85
35
11.42
3.59
13.65
4.29
15.83
4.46 16.92 5.09 18.34
5.49
20.86
6.36 22.48 7.28
37
11.42
3.83
13.65
4.60
15.83
4.76 16.92 5.32 18.34
5.83
20.86
6.75 22.48 7.73
39
11.42
4.08
13.65
4.91
15.83
5.07 16.92 5.52 18.34
6.18
20.86
7.15 22.48 8.21
41
11.42
4.23
13.65
5.10
15.83
5.26 16.92 5.72 18.34
6.45
20.86
7.53 22.48 8.59
43
11.42
4.38
13.65
5.20
15.83
5.45 16.92 6.10 18.34
6.61
20.86
7.91 22.48 8.97
45
11.42
4.59
13.65
5.86
15.83
6.24 16.92 6.73 18.34
7.39
20.86
8.68 22.48 9.36
48
11.42
5.39
13.65
6.15
15.83
6.92 16.92 7.68 18.34
8.44
20.86
9.21 22.48 9.97
Abbreviations:
CR: Combination ratio
TC: Total capacity (kW)
PI: Power input (comp outdoor fan motor) (kW)
Notes:
1. Shaded cells indicate rating condition.