V6-i VRF 50Hz
45
P
art
2
- O
ut
do
or
Unit
Engineer
ing Da
ta
Table 2-8.3: MVi-260WV2RN1(A) cooling capacity (continued)
Combination
(%)
(Capacity
index)
Outdoor
temperature
(°C DB)
Indoor temperature(°C DB/WB)
DB:20.8,WB:14
DB:23.3,WB:16
DB:25.8,WB:18
DB:27,WB:19
DB:28.2,WB:20
DB:30.7,WB:22
DB:32,WB:24
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
50%
-5
8.86
1.19
10.60
1.30
12.29
1.44 13.13 1.97 14.24
2.04
16.19
2.32 17.44 2.50
-2
8.86
1.21
10.60
1.32
12.29
1.46 13.13 2.02 14.24
2.08
16.19
2.35 17.44 2.54
0
8.86
1.22
10.60
1.33
12.29
1.48 13.13 2.02 14.24
2.10
16.19
2.39 17.44 2.58
2
8.86
1.24
10.60
1.35
12.29
1.50 13.13 2.03 14.24
2.14
16.19
2.40 17.44 2.63
4
8.86
1.25
10.60
1.37
12.29
1.52 13.13 2.04 14.24
2.18
16.19
2.46 17.44 2.70
6
8.86
1.28
10.60
1.39
12.29
1.55 13.13 2.05 14.24
2.22
16.19
2.50 17.44 2.78
8
8.86
1.30
10.60
1.42
12.29
1.59 13.13 2.06 14.24
2.25
16.19
2.54 17.44 2.87
10
8.86
1.33
10.60
1.45
12.29
1.62 13.13 2.04 14.24
2.32
16.19
2.61 17.44 2.91
12
8.86
1.35
10.60
1.48
12.29
1.65 13.13 2.06 14.24
2.36
16.19
2.65 17.44 2.95
14
8.86
1.38
10.60
1.51
12.29
1.68 13.13 2.07 14.24
2.40
16.19
2.70 17.44 3.01
16
8.86
1.41
10.60
1.55
12.29
1.72 13.13 2.07 14.24
2.43
16.19
2.75 17.44 3.06
18
8.86
1.44
10.60
1.58
12.29
1.75 13.13 2.08 14.24
2.48
16.19
2.79 17.44 3.12
20
8.86
1.47
10.60
1.63
12.29
1.78 13.13 2.18 14.24
2.53
16.19
2.84 17.44 3.18
21
8.86
1.48
10.60
1.70
12.29
1.82 13.13 2.29 14.24
2.55
16.19
2.87 17.44 3.21
23
8.86
1.58
10.60
1.84
12.29
1.95 13.13 2.44 14.24
2.60
16.19
2.92 17.44 3.28
25
8.86
1.70
10.60
1.98
12.29
2.09 13.13 2.60 14.24
2.68
16.19
3.07 17.44 3.50
27
8.86
1.81
10.60
2.13
12.29
2.24 13.13 2.80 14.24
2.84
16.19
3.27 17.44 3.73
29
8.86
1.94
10.60
2.29
12.29
2.40 13.13 2.89 14.24
3.02
16.19
3.48 17.44 3.97
31
8.86
2.07
10.60
2.45
12.29
2.56 13.13 3.08 14.24
3.21
16.19
3.70 17.44 4.23
33
8.86
2.21
10.60
2.63
12.29
2.74 13.13 3.24 14.24
3.41
16.19
3.93 17.44 4.50
35
8.86
2.36
10.60
2.82
12.29
2.93 13.13 3.34 14.24
3.60
16.19
4.17 17.44 4.77
37
8.86
2.51
10.60
3.02
12.29
3.12 13.13 3.49 14.24
3.82
16.19
4.43 17.44 5.08
39
8.86
2.68
10.60
3.22
12.29
3.33 13.13 3.62 14.24
4.06
16.19
4.69 17.44 5.39
41
8.86
2.78
10.60
3.35
12.29
3.45 13.13 3.75 14.24
4.23
16.19
4.94 17.44 5.64
43
8.86
2.88
10.60
3.41
12.29
3.58 13.13 4.00 14.24
4.34
16.19
5.19 17.44 5.89
45
8.86
3.01
10.60
3.84
12.29
4.09 13.13 4.42 14.24
4.85
16.19
5.69 17.44 6.14
48
8.86
3.54
10.60
4.04
12.29
4.54 13.13 5.04 14.24
5.54
16.19
6.04 17.44 6.54
Abbreviations:
CR: Combination ratio
TC: Total capacity (kW)
PI: Power input (comp outdoor fan motor) (kW)
Notes:
1. Shaded cells indicate rating condition.