8.4 Operation Modes and Functions
8.4.1 Fan mode
(
1) Outdoor fan and compressor stop.
(2) Temperature setting function is disabled,
and no setting temperature is displayed.
(3) Indoor fan can be set to
high/med/low/auto.
(4) The louver operates same as in cooling
mode.
(5) Auto fan:
For MS11M-09HRFN1-MW0W,
MS11M-12HRFN1-MV0W,
MS11M-18HRFN1-MU0W models:
a
b
c
d
6.0¡ã
C(42.8¡ã
F)
T1-24¡ã
C(75.2¡ã
F)
e
H
(H-L)*0.75+L
(H-L)*0.5+L
(H-L)*0.25+L
L
5.0¡ã
C(41.0¡ã
F)
4.0¡ã
C(39.2¡ã
F)
2.5¡ã
C(36.5¡ã
F)
1.0¡ã
C(33.8¡ã
F)
For MS11M-24HRDN1-MT0W model:
27.5¡ã
C(81.5¡ã
F)
T1
27.0¡ã
C(80.6¡ã
F)
High
Low
25.0¡ã
C(77.0¡ã
F)
Medium
25.5¡ã
C(77.9¡ã
F)
8.4.2 Cooling Mode
8.4.2.1 Compressor running rules
The maximum operation frequency of
compressor after starting submits to following
rule.
45¡ã
C(113¡ã
F)
40¡ã
C(104¡ã
F)
38¡ã
C(100.4¡ã
F)
31.5¡ã
C(88.7¡ã
F)
29.5¡ã
C(85.1¡ã
F)
22.0¡ã
C(71.6¡ã
F)
20.0¡ã
C(68.0¡ã
F)
Fmax=F4
Fmax=F7
Fmax=F8
Fmax=F6
Fmax=F3
T4
43¡ã
C(109.4¡ã
F)
Fmax: The maximum operation frequency of
compressor.
F1~F8: The detailed value of the compressor
operation frequency.
If users switch on AC by remote controller, the
compressor will run at the Fmax frequency for 7
minutes according to the outdoor ambient temp.
During the 7 minutes, the frequency limitation is
active. 7 minutes later, the compressor running
frequency will be controlled as below:
3.5¡ã
C(38.3¡ã
F)
-0.5¡ã
C(31.1¡ã
F)
T1-Ts
-1.0¡ã
C(30.2¡ã
F)
A
B
C
D
E
F
G
H
3.0¡ã
C(37.4¡ã
F)
2.5¡ã
C(36.5¡ã
F)
2.0¡ã
C(35.6¡ã
F)
1.5¡ã
C(34.7¡ã
F)
1.0¡ã
C(33.8¡ã
F)
0.5¡ã
C(32.9¡ã
F)
While the zones of A,B,C... are corresponding
to different compressor running frequency.
Note:
Содержание Mono 3D
Страница 14: ...12 5 Wiring Diagram 5 1 Indoor Unit MS11M 09HRFN1 MW0W MS11M 12HRFN1 MV0W MS11M 18HRFN1 MU0W...
Страница 15: ...13 MS11M 24HRDN1 MT0W...
Страница 16: ...14 5 2 Outdoor Unit MOC 09HFN1 MW0W MOC 12HFN1 MV0W...
Страница 17: ...15 MOF 18HFN1 MU0W...
Страница 18: ...16 MOG 24HFN1 MT0W MOC 09HFN1 MW0W MOC 12HFN1 MV0W...
Страница 19: ...17 MOF 18HFN1 MU0W...
Страница 20: ...18 MOG 24HFN1 MT0W...
Страница 29: ...27 T2 7 C 44 6 F the compressor frequency will not be limited...
Страница 53: ...51 Take the 9k model as example P U P V...
Страница 54: ...52 P W N U...
Страница 55: ...53 N V N W...