Maintenance Service and Trouble Shooting   

dissipation make the compressor running without stop. 

 

F. Electric leakage of appliance 

 

1)    Slight electric leakage 

 

Electric insulation has deteriorated due to being affected with damp, 

 

thus resulting in slight electric leakage. 

 

2)  Serious electric leakage 

 

Appliance case has become live due to faults occurred in some 

 

electric devices or the erroneous wiring in installing power cord plug or 

 

outlet by the user. This is very dangerous. 

 

3)    Electric leakage test 

 

a)    Slight electric leakage 

 

A tingle sense will be experienced as soon as you touch the metal parts 

 

of the appliance with your hand .When you test them with a test 

 

pencil ,its neon lamp will come on .In that case ,the first thing you need to 

 

do is to determine whether the grounding is perfect .If the grounding is no 

 

problem ,turn off the appliance immediately ,then check the insulation of 

 

electric circuits with an barometer . 

 

b)    Serious electric leakage 

 

Never touch the case body of the appliance, its door handle or other 

 

metal parts with your hand .Test the appliance with a test pencil ,it will 

 

light up intensively ;measure the resistance between the power cord plug 

 

and the case body with an avometer ,the reading will be zero (0

); in the 

 

worst case ,the fuse will be blown .Check the 3-prong outlet to see whether 

 

the live wire and the null line are inversely connected ,this makes the 

 

ground protection lead-out from the power cord plug being connected to the 

 

live wire .Another possibility is that the live wire and null line of the outdoor 

 

power supply circuit have been inversely connected accordingly ,this 

 

makes the null line become a live wire . 

 

G .Stronger vibration and loader noise 

 

1)

  Appliance placed improperly 

 

a)  Uneven ground 

 

Uneven ground will cause there ice maker to be placed 

 

unsteadily ,causing stronger vibration and noise during its operation . 

 

b)    Leveling screws not properly adjusted 

 

If    the leveling screws on appliance legs have not been adjusted 

 

properly ,vibration and noise will still occur even if the appliance has been 

 

placed on a level ground . 

 

2)

  Abnormal noise from compressor 

 

Three suspended spring inside the compressor case are out of 

 

balance ,and strike against the case ,moreover ,the wear of compressor 

 

parts may cause noise sometimes . 

 

3)

  Resonance of tubing and loosening of parts 

 

Improper and compact laying of tubes or the loosening of parts may 

 

cause vibration and noise . 

 

 

28 

 

Содержание HS-36I

Страница 1: ...ICE MAKER Service Manual Features Auto ice making technology Built in design Low noise operation Thick insulation for energy efficiency Latest No 2 micro biological technology 0...

Страница 2: ...CONTENT CONTENT 1 Content 1 2 Specifications 3 3 Function Schedule 7 4 System Flow Chart 8 5 Circuit Diagram 9 6 Maintenance Service and Trouble Shooting 10 7 Exploded View 30 8 List of Parts 31 1...

Страница 3: ...ity L HS 36I 28 Color Black Power Supply V Hz 220 50 Rated Input Power W Power Consumption kW h 24h Net Weight kg 30 Gross Weight kg Unit Dimension D W H mm Packing Dimension D W H mm Container Quanti...

Страница 4: ...Safety precautions Function Schedule Function Schedule Auto ice making technology Built in design Low noise operation Thick insulation for energy efficiency Latest No 2 micro biological technology 7...

Страница 5: ...t 1 Schematic diagram of System Flow Chart 2 Brief Description of System Flow Chart Model UL ZB28C2 is a direct cooling single system appliance When the appliance is just powered on the refrigerant fl...

Страница 6: ...agram Brief Description of Control Principle Model UL ZB28C2 is a direct cooling single system Ice marker A mechanical type of all the control is generally adopted The thermostat directly controls the...

Страница 7: ...ower NO Check and repair according to the section of the compessor doesn t work YES If compressor can run naturally and temperature raising of condenser is very low YES NO Refrigerant leak check and r...

Страница 8: ...capacity insufficient NO Check and repair according to the section of Cooling capacity is insuffcient YES 1 The thermostat was set at the coldest position 2 The ambient temperature is very high or th...

Страница 9: ...ing 3 Cooling capacity is insufficient Cooling capacity is insufficient Is the ambient YES temperature low than 16 C Check the therostat is correct YES NO Does the refrigerant leak siowly Adjust and i...

Страница 10: ...THE DOOR GASKET DOES NOT SEAL PROPERLY THE APPLIANCE DOES NOT HAVE THE CORRECT CLEARANCES VIBRATIONS CHECK TO ASSURE THAT THE APPLIANCE IS LEVEL THE APPLIANCE SEEMS TO MAKE TOO MUCH NOISE THE RATTLING...

Страница 11: ...pressure difference is still greater after the compressor has just stopped running the refrigerant will flow for a certain time therefore this sound is a normal phenomenon 2 A click sound can often be...

Страница 12: ...ce locations and natures of troubles should be determined according to their respective features therefore experience in servicing is very important to troubleshooting Service technicians with rich ex...

Страница 13: ...by a sound similar to water flowing this is the sound produced by the normal circulation of refrigerant within the evaporator In case only the gas flowing sound can be heard and there is no water flow...

Страница 14: ...ly due to a certain trouble With this method you can reject some suspicious troubles and finally make a correct judgment 7 Analysis of Troubles and Troubleshooting A Poor Refrigerating Effect The so c...

Страница 15: ...e refrigerant has been charged the liquid refrigerant that cannot evaporates in the evaporator will return to the compressor and thus a phenomenon of liquid striking will occur The liquid refrigerant...

Страница 16: ...porator regularly if you fail to do so the frost layer on the evaporator tubing will become thicker and thicker Heat conduction will be severely affected when the whole tubing is wrapped with a transp...

Страница 17: ...rigerant and seal the charging port B No Refrigerating The phenomenon that the compressor runs normally but no frost or only a little frost appears on the evaporator and the appliance temperature does...

Страница 18: ...these phenomena will appear intermittently sometimes the appliance works well and sometimes not well In order to determine whether it is clogged with ice heat the suspicious points with hot water to m...

Страница 19: ...ging with dirt 3 Troubles of Compressor a Breakage of gas suction and discharge valve blocks Analysis of Trouble The compressor works by means of the opening and closing of gas suction valve and disch...

Страница 20: ...he system Analysis of Trouble The residual air in the system will circulate together with the refrigerant in the system The major symptoms caused by this residual air is higher gas discharge pressure...

Страница 21: ...er supply c Abnormal thermal protection Analysis of Trouble The compressor current is within its normal range but the thermal protector actuates repeatedly Remedy Replace the thermal protector with a...

Страница 22: ...he user for buying a stabilizer so as to step up the voltage thus normal operation can be achieved 3 Check the thermal relay to see whether its contacts are closed Analysis of Trouble The contacts of...

Страница 23: ...on is caused mostly by poor lubrication such ad insufficient quantity of lubricant clogging in the lubricant oil line or intermittent lubricant oil supply Dirt and other impurities in the lubricant oi...

Страница 24: ...ated value the thermostat won t work thus the compressor runs continuously When the evaporation temperature in the system is too high the temperature sensing agent in the temperature sensor is also ho...

Страница 25: ...intensively measure the resistance between the power cord plug and the case body with an avometer the reading will be zero 0 in the worst case the fuse will be blown Check the 3 prong outlet to see wh...

Страница 26: ...ion becomes weaker or vanishes If the appliance has not been levelly placed put a level meter on its top table and adjust the leveling screws on its legs In case noise occurs from the compressor strik...

Страница 27: ...30 1 1 1 2 1 1 1 1...

Отзывы: