Maintenance Service and Trouble Shooting   

barometer. If short circuit occurs or the resistance of a certain phase is low, 

 

this means that short circuit does exist in the windings and/or between 

 

turns, and insulation layers have been burned or deteriorated. A 

 

mega meter can be used in this inspection, too. I f the insulation resistance 

 

is lower than 2 M

, this means that the insulation layer is already 

 

breakdown. If the motor has been burned, repair it or replaced it with a new 

 

one. 

 

b) Fault of control relay 

 

Analysis of Trouble 

 

Overheat, burnout or wear of control relay contacts may occur generally. 

 

All these will cause poor contact in electricity. 

 

Remedy 

 

Dismantle it to repair, or replace it with a new one. 

 

c)    Poor electric contactor in thermostat 

 

Analysis of Trouble 

 

Burnout of contactor and leakage of temperature sensing agent may 

 

occur generally. 

 

Remedy 

 

Replace the old with a new one. 

 

d)    Check the terminals for loose connection and electric circuits for 

 

other abnormal phenomena. 

 

5) Mechanical faults of compressor 

 

a)    Seizing of shaft 

 

This phenomenon is caused mostly by poor lubrication, such ad 

 

insufficient quantity of lubricant, clogging in the lubricant oil line, or 

 

intermittent lubricant oil supply. Dirt and other impurities in the lubricant oil 

 

will increase its viscosity and cause the shaft to be seized. Copper plating 

 

may also result in seizing of shaft. 

 

b) Seizing of piston 

 

This is caused by too small fit clearance between the piston and 

 

cylinder or expansion due to heat. 

 

Judgment of seizing shaft and piston: After the appliance has been 

 

powered on, the compressor will not start and run, but a slight hum sound 

 

can be heard, and several seconds later, thermal protective relay will 

 

actuate and make the contacts open; this process will occur repeatedly, but 

 

the compressor cannot be started. 

 

E. Compressor won't stop 

 

Sometimes, the compressor will run continuously(for several hours or 

 

run without end), If the food placed in the appliance is not too much, there 

 

may be the following two situations: i) the appliance very low, this means 

 

that the control system is probably out of order; ii) the control system works 

 

normally, and there are troubles in the refrigerating system or other parts. 

 

1) Temperature is set improperly 

 

a)    The temperature control knob is set to the "coldest" position. This 

 

 

26 

 

Содержание HS-36I

Страница 1: ...ICE MAKER Service Manual Features Auto ice making technology Built in design Low noise operation Thick insulation for energy efficiency Latest No 2 micro biological technology 0...

Страница 2: ...CONTENT CONTENT 1 Content 1 2 Specifications 3 3 Function Schedule 7 4 System Flow Chart 8 5 Circuit Diagram 9 6 Maintenance Service and Trouble Shooting 10 7 Exploded View 30 8 List of Parts 31 1...

Страница 3: ...ity L HS 36I 28 Color Black Power Supply V Hz 220 50 Rated Input Power W Power Consumption kW h 24h Net Weight kg 30 Gross Weight kg Unit Dimension D W H mm Packing Dimension D W H mm Container Quanti...

Страница 4: ...Safety precautions Function Schedule Function Schedule Auto ice making technology Built in design Low noise operation Thick insulation for energy efficiency Latest No 2 micro biological technology 7...

Страница 5: ...t 1 Schematic diagram of System Flow Chart 2 Brief Description of System Flow Chart Model UL ZB28C2 is a direct cooling single system appliance When the appliance is just powered on the refrigerant fl...

Страница 6: ...agram Brief Description of Control Principle Model UL ZB28C2 is a direct cooling single system Ice marker A mechanical type of all the control is generally adopted The thermostat directly controls the...

Страница 7: ...ower NO Check and repair according to the section of the compessor doesn t work YES If compressor can run naturally and temperature raising of condenser is very low YES NO Refrigerant leak check and r...

Страница 8: ...capacity insufficient NO Check and repair according to the section of Cooling capacity is insuffcient YES 1 The thermostat was set at the coldest position 2 The ambient temperature is very high or th...

Страница 9: ...ing 3 Cooling capacity is insufficient Cooling capacity is insufficient Is the ambient YES temperature low than 16 C Check the therostat is correct YES NO Does the refrigerant leak siowly Adjust and i...

Страница 10: ...THE DOOR GASKET DOES NOT SEAL PROPERLY THE APPLIANCE DOES NOT HAVE THE CORRECT CLEARANCES VIBRATIONS CHECK TO ASSURE THAT THE APPLIANCE IS LEVEL THE APPLIANCE SEEMS TO MAKE TOO MUCH NOISE THE RATTLING...

Страница 11: ...pressure difference is still greater after the compressor has just stopped running the refrigerant will flow for a certain time therefore this sound is a normal phenomenon 2 A click sound can often be...

Страница 12: ...ce locations and natures of troubles should be determined according to their respective features therefore experience in servicing is very important to troubleshooting Service technicians with rich ex...

Страница 13: ...by a sound similar to water flowing this is the sound produced by the normal circulation of refrigerant within the evaporator In case only the gas flowing sound can be heard and there is no water flow...

Страница 14: ...ly due to a certain trouble With this method you can reject some suspicious troubles and finally make a correct judgment 7 Analysis of Troubles and Troubleshooting A Poor Refrigerating Effect The so c...

Страница 15: ...e refrigerant has been charged the liquid refrigerant that cannot evaporates in the evaporator will return to the compressor and thus a phenomenon of liquid striking will occur The liquid refrigerant...

Страница 16: ...porator regularly if you fail to do so the frost layer on the evaporator tubing will become thicker and thicker Heat conduction will be severely affected when the whole tubing is wrapped with a transp...

Страница 17: ...rigerant and seal the charging port B No Refrigerating The phenomenon that the compressor runs normally but no frost or only a little frost appears on the evaporator and the appliance temperature does...

Страница 18: ...these phenomena will appear intermittently sometimes the appliance works well and sometimes not well In order to determine whether it is clogged with ice heat the suspicious points with hot water to m...

Страница 19: ...ging with dirt 3 Troubles of Compressor a Breakage of gas suction and discharge valve blocks Analysis of Trouble The compressor works by means of the opening and closing of gas suction valve and disch...

Страница 20: ...he system Analysis of Trouble The residual air in the system will circulate together with the refrigerant in the system The major symptoms caused by this residual air is higher gas discharge pressure...

Страница 21: ...er supply c Abnormal thermal protection Analysis of Trouble The compressor current is within its normal range but the thermal protector actuates repeatedly Remedy Replace the thermal protector with a...

Страница 22: ...he user for buying a stabilizer so as to step up the voltage thus normal operation can be achieved 3 Check the thermal relay to see whether its contacts are closed Analysis of Trouble The contacts of...

Страница 23: ...on is caused mostly by poor lubrication such ad insufficient quantity of lubricant clogging in the lubricant oil line or intermittent lubricant oil supply Dirt and other impurities in the lubricant oi...

Страница 24: ...ated value the thermostat won t work thus the compressor runs continuously When the evaporation temperature in the system is too high the temperature sensing agent in the temperature sensor is also ho...

Страница 25: ...intensively measure the resistance between the power cord plug and the case body with an avometer the reading will be zero 0 in the worst case the fuse will be blown Check the 3 prong outlet to see wh...

Страница 26: ...ion becomes weaker or vanishes If the appliance has not been levelly placed put a level meter on its top table and adjust the leveling screws on its legs In case noise occurs from the compressor strik...

Страница 27: ...30 1 1 1 2 1 1 1 1...

Отзывы: