Maintenance Service and Trouble Shooting   

 

5  Normal Phenomena

Not Troubles for Appliances 

 

 

In a domestic appliance, there is not only a complicated electric control 

 

system, but also a refrigerating system that is difficult to discern whether it 

 

is in a good working condition. Both the systems are related and affect   
each other. If a certain part of a appliance works abnormally .Its 

 

refrigerating efficiency will decrease ,operation properties will become 

 

unstable ,or even it cannot be used normally for those serious cases. 

 

Appliances are generally of larger volume ,once troubles appear ,to 

 

send them to a service department is really a tough thing ,if such is the 

 

case ,the user will always be in suspense ,sometimes ,normal phenomena 

 

will be erroneously regarded as troubles .Therefore ,before we deal with 

 

the topics of frequently occurring troubles of appliances and their 

 

remedies ,we should firstly give a brief account of some normal 

 

phenomena which are not troubles .In case any one of such phenomena 

 

occurs ,there is no need to worry about it ,and the user can use it at total 

 

ease . 

 

1).When the compressor of a appliance has just stopped running ,a 

 

rumbling sound can be heard from inside its evaporator .This is a sound 

 

caused by the flowing of refrigerant in the evaporator tubing .Because the 

 

pressure difference is still greater after the compressor has just stopped 

 

running ,the refrigerant will flow for a certain time , therefore ,this sound is a 

 

normal phenomenon. 

 

2).A click sound can often be heard from the appliance .This is a 

 

normal sound produced by the pull-in or release of the armature of a 

 

current deadweight start relay when starting the compressor .The 

 

compressor motor will produce a slight and uniform sound while it is 

 

running .This sound is not easy to be heard in the daytime ,but of course it 

 

can be heard distinctly at night. 

 

3).The compressor consists of an electric motor and a compressing 

 

apparatus .During its normal operation ,the motor's stator core and 

 

windings will rise to a temperature in the range of 100

°

C~110

°

C ,and the 

 

temperature of the piston and cylinder of the compressing mechanism can 

 

also reach as above 100

°

C due to the heat produced when compressing 

 

refrigerant .Most of the heat radiates to the air through the compressor 

 

casing ,therefore ,its casing is generally at a temperature between 85

°

C ~90

°

C

 

,it is very hot ,particularly in summer when the ambient temperature is   

higher .All these are normal phenomena .   

4).For the direct cooling appliance ,a kind of irregular crack sound can   

be often heard when the compressor is running for a certain period of time   
or has just stopped its running .This sound is caused by the stress relief   
due to expansion and contraction when temperature changes ,and will not   

affect the normal application of appliance .   

14 

 

Содержание HS-36I

Страница 1: ...ICE MAKER Service Manual Features Auto ice making technology Built in design Low noise operation Thick insulation for energy efficiency Latest No 2 micro biological technology 0...

Страница 2: ...CONTENT CONTENT 1 Content 1 2 Specifications 3 3 Function Schedule 7 4 System Flow Chart 8 5 Circuit Diagram 9 6 Maintenance Service and Trouble Shooting 10 7 Exploded View 30 8 List of Parts 31 1...

Страница 3: ...ity L HS 36I 28 Color Black Power Supply V Hz 220 50 Rated Input Power W Power Consumption kW h 24h Net Weight kg 30 Gross Weight kg Unit Dimension D W H mm Packing Dimension D W H mm Container Quanti...

Страница 4: ...Safety precautions Function Schedule Function Schedule Auto ice making technology Built in design Low noise operation Thick insulation for energy efficiency Latest No 2 micro biological technology 7...

Страница 5: ...t 1 Schematic diagram of System Flow Chart 2 Brief Description of System Flow Chart Model UL ZB28C2 is a direct cooling single system appliance When the appliance is just powered on the refrigerant fl...

Страница 6: ...agram Brief Description of Control Principle Model UL ZB28C2 is a direct cooling single system Ice marker A mechanical type of all the control is generally adopted The thermostat directly controls the...

Страница 7: ...ower NO Check and repair according to the section of the compessor doesn t work YES If compressor can run naturally and temperature raising of condenser is very low YES NO Refrigerant leak check and r...

Страница 8: ...capacity insufficient NO Check and repair according to the section of Cooling capacity is insuffcient YES 1 The thermostat was set at the coldest position 2 The ambient temperature is very high or th...

Страница 9: ...ing 3 Cooling capacity is insufficient Cooling capacity is insufficient Is the ambient YES temperature low than 16 C Check the therostat is correct YES NO Does the refrigerant leak siowly Adjust and i...

Страница 10: ...THE DOOR GASKET DOES NOT SEAL PROPERLY THE APPLIANCE DOES NOT HAVE THE CORRECT CLEARANCES VIBRATIONS CHECK TO ASSURE THAT THE APPLIANCE IS LEVEL THE APPLIANCE SEEMS TO MAKE TOO MUCH NOISE THE RATTLING...

Страница 11: ...pressure difference is still greater after the compressor has just stopped running the refrigerant will flow for a certain time therefore this sound is a normal phenomenon 2 A click sound can often be...

Страница 12: ...ce locations and natures of troubles should be determined according to their respective features therefore experience in servicing is very important to troubleshooting Service technicians with rich ex...

Страница 13: ...by a sound similar to water flowing this is the sound produced by the normal circulation of refrigerant within the evaporator In case only the gas flowing sound can be heard and there is no water flow...

Страница 14: ...ly due to a certain trouble With this method you can reject some suspicious troubles and finally make a correct judgment 7 Analysis of Troubles and Troubleshooting A Poor Refrigerating Effect The so c...

Страница 15: ...e refrigerant has been charged the liquid refrigerant that cannot evaporates in the evaporator will return to the compressor and thus a phenomenon of liquid striking will occur The liquid refrigerant...

Страница 16: ...porator regularly if you fail to do so the frost layer on the evaporator tubing will become thicker and thicker Heat conduction will be severely affected when the whole tubing is wrapped with a transp...

Страница 17: ...rigerant and seal the charging port B No Refrigerating The phenomenon that the compressor runs normally but no frost or only a little frost appears on the evaporator and the appliance temperature does...

Страница 18: ...these phenomena will appear intermittently sometimes the appliance works well and sometimes not well In order to determine whether it is clogged with ice heat the suspicious points with hot water to m...

Страница 19: ...ging with dirt 3 Troubles of Compressor a Breakage of gas suction and discharge valve blocks Analysis of Trouble The compressor works by means of the opening and closing of gas suction valve and disch...

Страница 20: ...he system Analysis of Trouble The residual air in the system will circulate together with the refrigerant in the system The major symptoms caused by this residual air is higher gas discharge pressure...

Страница 21: ...er supply c Abnormal thermal protection Analysis of Trouble The compressor current is within its normal range but the thermal protector actuates repeatedly Remedy Replace the thermal protector with a...

Страница 22: ...he user for buying a stabilizer so as to step up the voltage thus normal operation can be achieved 3 Check the thermal relay to see whether its contacts are closed Analysis of Trouble The contacts of...

Страница 23: ...on is caused mostly by poor lubrication such ad insufficient quantity of lubricant clogging in the lubricant oil line or intermittent lubricant oil supply Dirt and other impurities in the lubricant oi...

Страница 24: ...ated value the thermostat won t work thus the compressor runs continuously When the evaporation temperature in the system is too high the temperature sensing agent in the temperature sensor is also ho...

Страница 25: ...intensively measure the resistance between the power cord plug and the case body with an avometer the reading will be zero 0 in the worst case the fuse will be blown Check the 3 prong outlet to see wh...

Страница 26: ...ion becomes weaker or vanishes If the appliance has not been levelly placed put a level meter on its top table and adjust the leveling screws on its legs In case noise occurs from the compressor strik...

Страница 27: ...30 1 1 1 2 1 1 1 1...

Отзывы: