Standby screen
(1) Display the current test mode: Message “ACW” for AC voltage testing, “DCW”
for DC voltage testing, “IR” for insulation impedance testing
(2) Readings of the voltage, current (resistance in IR mode), and test time of the
measurement output port now. It displays the current voltage and test time
settings if no test is running now.
(3) Display the current status of your machine as illustrated in the table below:
Status display
Description
READY
Your machine is ready for testing now, press the TEST key to
begin testing
TEST
Testing now
WAIT
The Trig Wait Time which can be set up in the CONFIG menu
WAIT KEY
Waiting for the trigger signal for the next test
PASS
Tested successfully (qualified goods)
Break Down
Leak current exceeds the maximum measurement
Arcing
Arc exceeds the upper limit
Lo-Limit
Measurement exceeds the lower limit
Hi-limit
Measurement exceeds the upper limit
FAIL
At least one step in a multi-step test failed
INTER-LOCK
High voltage safety lock on
VOLT-ERROR
Voltage output error
OPEN
Test wire disconnection error